Published November 1, 2023 | Version v1

Retrofit strategies to mitigate overheating linking urban climate modeling and urban building simulations with outdoor comfort. An urban sector in Malaga (Spain)

  • 1. Universidad Nacional de La Plata (UNLP)
  • 2. ROR icon Universidad de Sevilla

Description

This work evaluates the cooling effect of retrofit strategies on urban buildings and outdoor comfort in an urban sector in Malaga on one of the hottest days. The methodology links urban climate modeling and urban building simulations with outdoor comfort. The solar reflectance (SR) of roofs, urban surfaces and green areas and their forestation increases after the retrofit. Only the SR façade remains the same, be it in the current or the retrofit scenarios: 0.3. Both façade retrofit strategies consist of an opaque double skin façade (ODSF) with ceramic or metal tiles. Energy cooling is reduced by 52.51% with ceramic and by 52.57% with metal ODSF while urban comfort improves after retrofit: Universal Thermal Comfort Index (UTCI) decreases by 0.62 ◦C and Mean Radiant Temperature (MRT) decreases by 2.58 ◦C. Simultaneously, seven points at the pedestrian level assess outdoor comfort in different urban canyons. UTCI decreases more with the metal than with the ODSF ceramic. Regardless the canyon height, the width ratio or the orientation, the UTCI decreases between 2.45 ◦C and 4.86 ◦C when under a tree and it decreases more as S/N canyons narrow. This methodology and insights help stakeholders, designers, planners, and policy-makers make data-driven decisions to mitigate overheating and UHI in Mediterranean cities with similar urban building and canyon morphology.

Files

E&B_23.pdf

Files (313.9 kB)

Name Size
md5:1a8ff3d90a11378aceb56fa694e8f239
313.9 kB Preview Download

Additional details

Dates

Issued
2023-11-01