Published November 25, 2011
| Version 2933
Journal article
Open
Flexural Strength and Ductility Improvement of NSC beams
Authors/Creators
Description
In order to calculate the flexural strength of
normal-strength concrete (NSC) beams, the nonlinear actual concrete
stress distribution within the compression zone is normally replaced
by an equivalent rectangular stress block, with two coefficients of α
and β to regulate the intensity and depth of the equivalent stress
respectively. For NSC beams design, α and β are usually assumed
constant as 0.85 and 0.80 in reinforced concrete (RC) codes. From an
earlier investigation of the authors, α is not a constant but significantly
affected by flexural strain gradient, and increases with the increasing
of strain gradient till a maximum value. It indicates that larger
concrete stress can be developed in flexure than that stipulated by
design codes. As an extension and application of the authors- previous
study, the modified equivalent concrete stress block is used here to
produce a series of design charts showing the maximum design limits
of flexural strength and ductility of singly- and doubly- NSC beams,
through which both strength and ductility design limits are improved
by taking into account strain gradient effect.
Files
2933.pdf
Files
(369.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:79ae03dde96514232401f4a229d37ee0
|
369.6 kB | Preview Download |
Additional details
References
- ACI Committee 318, Building Code Requirements for Reinforced Concrete and Commentary ACI 318M-08, Manual of Concrete Practice, American Concrete Institute, Michigan, USA, 465pp, 2008.
- A.H. Mattock, L.B. Kriz, and E. Hognestad , "Rectangular concrete stress distribution in ultimate strength design", ACI Journal, vol. 57, no. 1, pp.875-928, 1961.
- E. Hognestad, N.W. Hanson, and D. McHenry, "Concrete stress distribution in ultimate strength design", ACI Journal, vol. 52, no. 12, pp.455-480, 1955.
- European Committee for Standardization (ECS), Eurocode 2: Design of Concrete Structures: Part 1-1: General Rules and Rules for Buildings, British Standard Institution, London, UK, 225pp, 2004.
- G. Fathifazl, A.G. Razaqpur, O.B. Isgor, A. Abbas, B. Fournier and S. Foo, "Shear strength of reinforced recycled concrete beams without stirrups", Magazine of Concrete Research, vol. 61, no. 7, pp.477-490, 2009.
- H. J. Pam, A. K. H. Kwan, and J. C. M. Ho, "Post-peak behavior and flexural ductility of doubly reinforced normal- and high-strength concrete beams," Structural Engineering and Mechanics, vol. 12, no. 5, pp.459-474, 2001.
- H. J. Pam, A. K. H. Kwan, and M. S. Islam, "Flexural strength and ductility of reinforced normal- and high-strength concrete beams," Structures and Buildings, vol. 146, no. 4, pp.381-389, 2001.
- H.H.H. Ibrahim and J.G. MacGregor, "Flexural behavior of laterally reinforced high-strength concrete sections", ACI Structural Journal, vol. 93, no. 6, pp.674-684, 1996.
- H.H.H. Ibrahim and J.G. MacGregor, "Modification of the ACI rectangular stress block for high-strength concrete", ACI Structural Journal, vol. 94, no.1, pp.40-48, 1997. [10] J. C. M. Ho and J. Peng, "Strain gradient effects on flexural strength design of normal-strength concrete beams," The Structural Design of Tall and Special Buildings, doi: 10.1002/tal.655, 2010. [11] J. C. M. Ho and J. Peng, "Strain gradient effects on flexural strength design of normal-strength concrete columns," Engineering Structures, vol. 33, no. 1, pp.18-31, 2011. [12] M. Pecce and G. Fabbrocino, "Plastic rotation capacity of beams in normal and high-performance concrete", ACI Structural Journal, vol. 96, no. 2, pp.290-296, 1999. [13] P.G. Debernardi and M. Taliano, "On evaluation of rotation capacity for reinforced concrete beams", ACI Structural Journal, vol. 99, no. 3, pp.360-368, 2002. [14] S.A. Ashour, "Effect of compressive strength and tensile reinforcement ratio on flexural behaviour of high-strength concrete beams", Engineering Structures, vol. 25, no. 8, pp.1083-1096, 2000. [15] S.S.E. Lam, B. Wu, Z.Q. Liu and Y.L. Wong, "Experimental study on seismic performance of coupling beams not designed for ductility", Structural Engineering and Mechanics, vol. 28, no. 3, pp.317-333, 2008. [16] Standards New Zealand, NZS 3101, Concrete Structures Standard, Part 1 - The Design of Concrete Structures, Concrete Standard New Zealand, Wellington, New Zealand, 2006. [17] T.H. Tan and N.B. Nguyen, "Determination of stress-strain curves of concrete from flexure tests", Magazine of Concrete Research, vol. 56, no. 4, pp.243-250, 2004. [18] T.H. Tan and N.B. Nguyen, "Flexural behavior of confined high-strength concrete columns", ACI Structural Journal, vol. 102, no. 2, pp.198-205, 2005. [19] T. Ozbakkaloglu and M. Saatcioglu, "Rectangular stress block for high-strength concrete", ACI Structural Journal, vol. 101, no. 4, pp.475-483, 2004.