Microfluidic systems on CubeSats: State of the art and its application on the BIXO mission
Authors/Creators
- 1. UVigo SpaceLab
- 2. University of Vigo
Description
Microfluidic systems are an indispensable part of bacteriological experiments carried out inside nanosatellites, since the growth medium needed to feed the biologic organisms is pumped along them. BIXO, Bacteriological Intercommunication eXperiment in Orbit, is the mission developed by the UVigo Spacelab team that will conduct an experiment involving Chromobacterium violaceum, a bacteria that segregates a violet pigment when it establishes contact with cells from another colony. This process is called Quorum Sensing (QS) and the behaviour of the colonies can be studied through the light absorbance level evolution resulting from it. For this purpose, a microfluidic system will be placed inside the Pressure Vessel (PV) in order to store, pump and control the nutrient-rich liquid that will activate the growth process of C. violaceum at three different times during the nine-month duration of the mission.
During the first section of this paper, several microfluidic architectures from previous biological cubesat missions will be discussed. Although there is little scientific literature concerning microfluidics in space, information collected from eight different biological experiments performed inside nanosatellites provides extraordinary knowledge and huge experience transfer in the development of this equipment. Some of these missions include EcAMSat and BioSentinel, by NASA; Spacedot, from the Aristotle University of Thessaloniki; and Morebac, from the KTH Royal Institute of Technology.
Finally, the configuration and design of the microfluidic system that will be mounted inside BIXO’s PV will be justified in accordance with the information previously gathered. Nevertheless, it is important to keep in mind that, when designing an equipment like this, the optimal architectural configuration is the one that better fits the requirements of the mission, therefore some decisions were taken considering not only the scientific literature but also the particular characteristics of BIXO.
Files
SSSIF2023-MicrofluidicsystemsinCubeSats.pdf
Additional details
References
- Camanzo Mariño, Alejandro & Diz-Folgar, Manuel & Vale-Xoubanova, Manuel & Castro, Pablo & Parafita, Pedro & Amaro-Losada, Lucía & Agelet, Fernando & Bodelon, Gustavo & Sieiro, Carmen & Pastoriza-Santos, Isabel & Pérez-Juste, Jorge. (2022). BIXO, a student-led CubeSat mission for education and astrobiology research. doi: 10.13140/RG.2.2.23532.85125.
- C. Kitts, J. Hines, E. Agasid, A. Ricco, B. Yost, K. Ronzano, and J. Puig-Suari, "The genesat- 1 microsatellite mission: A challenge in small satellite design," 2006.
- B. Harandi, S. Ng, L. C. Liddell, D. M. Gentry, and S. R. Santa Maria, "Fluidic-based instruments for space biology research in cubesats," F. in Space Technologies, Ed., 2022.
- N. Aeronautics and S. A. (NASA), PharmaSat Fact Sheet, 2009.
- A. Ricco, M. Parra, D. Niesel, M. Piccini, D. Ly, M. McGinnis, A. Kudlicki, J. Hines, L. Timucin, C. Beasley, R. Ricks, M. McIntyre, C. Friedericks, M. Henschke, R. Leung, M. Diaz-Aguado, C. Kitts, I. Mas, M. Rasay, and B. Yost, PharmaSat: Drug dose response in microgravity from a free-flying integrated biofluidic/optical cultureand- analysis satellite, 02 2011, vol. 7929.
- C. Kitts, K. Ronzano, R. Rasay, I. Mas, J. Acain, M. Neumann, L. Bica, P. Mahacek, G. Minelli, E. Beck, S. Li, B. Gamp, S. Agnew, J. Shepard, J. Hines, E. Agasid, C. Friedericks, M. Piccini, M. Parra, and M. Mcginnis, Initial Flight Results from the PharmaSat Biological Microsatellite Mission, 01 2009.
- G. Minelli, A. Ricco, C. Beasley, J. Hines, E. Agasid, B. Yost, D. Squires, C. Friedericks, M. Piccini, G. Defouw, M. Mcintyre, R. Ricks, M. Parra, M. Diaz-Aguado, L. Timucin, M. Henschke, M. Lera, M. Tan, M. Cohen, and L. Bica, O/OREOS Nanosatellite: A Multi- Payload Technology Demonstration, 08 2010.
- N. Aeronautics and S. A. (NASA), Spore- Sat,Investigating the Gravitational Threshold for Calcium Ion Channel, Activation using a Nanosatellite Platform-Based, 2013.
- W. W. A. Wan Salim, J. H. Park, J. Rickus, A. Rademacher, A. Ricco, A. Schooley, J. Benton, B. Wickizer, A. Martinez, N. Mai, M. Rasay, D. Porterfield, L. Brownston, M. Cote, G. Defouw, M. Henschke, C. Kitts, E. Luzzi, M. Perez, and A. Sweet, SPORESAT: A NANOSATELLITE PLATFORM LABON- A-CHIP SYSTEM FOR INVESTIGATING GRAVITY THRESHOLD OF FERN SPORE SINGLE-CELL CALCIUM CURRENTS, 05 2014, pp. 111–114.
- M. R. Padgen, T. N. Chinn, C. R. Friedericks, M. P. Lera, M. Chin, M. P. Parra, M. E. Piccini, A. J. Ricco, and S. M. Spremo, The EcAMSat fluidic system to study antibiotic resistance in low earth orbit: Development and lessons learned from space flight, 2020, vol. 173, pp. 449–459. [Online]. Available: https://www.sciencedirect.com/science/article /pii/S009457652030093X
- A. Matin, J.-H. Wang, M. Keyhan, R. Singh, M. Benoit, M. P. Parra, M. R. Padgen, A. J. Ricco, M. Chin, C. R. Friedericks, T. N. Chinn, A. Cohen, M. B. Henschke, T. V. Snyder, M. P. Lera, S. S. Ross, C. M. Mayberry, S. Choi, D. T. Wu, M. X. Tan, T. D. Boone, C. C. Beasley, M. E. Piccini, and S. M. Spremo, Payload hardware and experimental protocol development to enable future testing of the effect of space microgravity on the resistance to gentamicin of uropathogenic Escherichia coli and its sigma s deficient mutant, 2017, vol. 15, pp. 1–10. [Online]. Available: https://www.sciencedirect.com/science/article/ pii/S2214552417300251
- S. Massaro Tieze, L. C. Liddell, S. R. Santa Maria, and S. Bhattacharya, BioSentinel: A Biological CubeSat for Deep Space Exploration, 0, vol. 0, no. 0, p. null, pMID: 32282239. [Online]. Available: https://doi.org/10.1089/ast.2019.2068
- M. Padgen, L. Liddell, S. Bhardwaj, D. Gentry, D. Marina, M. Parra, T. Boone, M. Tan, L. Ellingson, A. Rademacher, J. Benton, A. Schooley, A. Mousavi, C. Friedericks, R. Hanel, A. Ricco, S. Bhattacharya, and S. Santa Maria, BioSentinel: A Biofluidic Nanosatellite Monitoring Microbial Growth and Activity in Deep Space, 02 2021.
- A. Arampatzis, A. Zaras, P. Matsatsos, O. Ousoultzoglou, D. Nikolopoulou, E. Sandaltzoupoulou, C. Giannitsis, A. Theocharis, and E. Chatziargyriou, Payload Design Definition and Justification File DDJF PL, 2021.
- A. Nygren and A. Ramm, Microfluidics system for the MOREBAC astrobiology experiment module : Design of a cubesat module, 2018. [16] Cell Therapy Solutions, 2022, p. 9. [Online]. Available: https://www.celltherapy.saintgobain. com
- Model RP-Q Series Miniature Peristaltic Pump, DC Power, Discharge Flowrates to 3.0 ml/min, Clark Solutions. [Online]. Available: https://www.clarksol.com/wpcontent/ uploads/2019/07/RPQ1.pdf [18] ULTRA-MINIATURE LATCHING 2- PORT HIGH DENSITY INTERFACE (HDI) SOLENOID VALVE, The Lee Company, 2020. [Online]. Available: https://www.theleeco.com/uploads/2021/11/PDS- 135-2020-06-UltraMiniatureLatching2- PortHighDensityInterface-HDISolenoidValve. pdf
- Technical Hydraulic Handbook, The Lee Company, 2019. [Online]. Available: https://www.ddp.nl/wpcontent/ uploads/2020/07/Precision-Hydraulics- 12th-Edition-2019.pdf
- Catalogue mp6 accessories, Bartels mikrotechnik, 2023. [Online]. Available: https : //www.bartels − mikrotechnik.de/wp − content/uploads/simple − file − list/EN/Manuals − and − Data − Sheets/mp6accessoriesCatalogue.pdf
- Y. Bessho, Y. Wang, K. Uesugi, and K. Morishima, A venous valve-like check valve for microfluidic device, 11 2018.
- Elveflow. Microfluidic calculator. [Online]. Available: https://www.elveflow.com/microfluidiccalculator/
- T. Daniel, S. White, and J. Lewis, Chaotic mixing in three-dimensional microvascular networks fabricated by direct-write assembly, 05 2003, vol. 2, pp. 265–71.