Published August 18, 2023 | Version v20230818

A possible case of hypertrophic osteopathy in osteological remains representing a cattle hide from a Roman villa in England: Supporting X-ray microtomography DATA

  • 1. μ-VIS X-ray Imaging Centre, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom, SO17 1BJ, UK
  • 2. Historic England, Fort Cumberland, Portsmouth, PO4 9LD, UK
  • 3. Department of Microbial Sciences, School of Biosciences and Medicine, AX Building, Stag Hill Campus, University of Surrey, Guildford, GU2 7XH, UK

Description

Data Deposition: "A Possible Case of Hypertrophic Osteopathy in Osteological Remains Representing a Cattle Hide from a Roman Villa in England"

μCT imaging was conducted to evaluate the volumetric manifestation of bone alterations. μCT imaging was performed using a Nikon XTEK XTH 225 kVp micro-focus CT system at the μ-VIS X-ray Imaging Centre (www.muvis.org) at the University of Southampton. Imaging was conducted at 150 kVp / 76 μA without any beam pre-filtration, with a voxel-edge size of 21.5 μm (cf. supplementary data for more details). Volumetric analysis and visualisation were conducted in “Dragonfly” (v. 2022.1; Object Research Systems (ORS) Inc, Montreal, Canada, 2020; software available at http://www.theobjects.com/dragonfly).

We have deposited the following data associated with the publication for open access and further research:

  • 20230523_HMX_3522_OLK_5082-2C [2023-05-23 12.54.40].zip
    Raw Micro CT Data - This file comprises radiographs and acquisition files obtained using the Nikon CT system. These radiographs are fundamental to the microCT acquisition process and form the basis for subsequent analysis.
  • 20230523_HMX_3522_OLK_5082-2C_recon_1522x1512x2000x8bit
    Reconstructed 8-bit Volume Data - Contained within this file are the reconstructed volume data derived from File 1. The volume dimensions are indicated in the filename as _DimX(pixels)xDimY(pixels)xDimZ(pixels)xbitDepth. The provided voxel edge X,Y,Z is 0.02153266 mm.
  • Visualisation_project.ORSSession
     ORD Dragonfly Visualization Project - This file is a visualisation project created in "Dragonfly" software (v. 2022.1; Object Research Systems Inc, Montreal, Canada, 2020). To access the detailed visualisations and perform further analysis, please open this file using Dragonfly software. The software is available at http://www.theobjects.com/dragonfly.
  • Videos:
    • Acquisition.avi
      360o radiographic inspection of studied specimen. Radiographs collected during μCT aquisition and rendered into a video using Fiji/ImageJ
    • Acquisition_small.m4v
      Compressed version of Acquisition.avi
    • XY-YZ-CombinedVideo.avi
      Side-by-side single-slice roll of XY and YZ planes. The roll is focused around the defect.
    • XY-YZ-CombinedVideo_small.m4v
      Compressed version of XY-YZ-CombinedVideo.avi

Feel free to utilise these deposited files to delve into the findings presented in our publication. We encourage fellow researchers and interested parties to explore and engage with the data for deeper insights and collaborative studies.

Files

20230523_HMX_3522_OLK_5082-2C [2023-05-23 12.54.40].zip

Files (28.2 GB)

Name Size
md5:4c590b3f275ed3a7a9bdb45e7e23f2be
18.4 GB Preview Download
md5:feb92df42608806956370f06e2464db9
4.6 GB Download
md5:0fb1ea04555818ecf093a28131913e2f
212.8 MB Download
md5:12865d510067bcbb1ba18ee043280264
92.9 MB Download
md5:972d8da31eac100269f7a574b644d9a3
4.6 GB Download
md5:18b6a333412ee38b34a8ee2e5c231ec7
186.8 MB Download
md5:e879bcb680bf2237dbd2790ac86bd7b2
99.9 MB Download

Additional details

Related works

Is supplement to
Publication: 10.1016/j.ijpp.2025.11.003 (DOI)