Published August 14, 2023 | Version 1.0.0
Dataset Open

[Luminescence Dataset] The loess sequence of Dolní Věstonice, Czech Republic: A new OSL‐based chronology of the last climatic cycle

  • 1. Department of Geography, Justus-Liebig-University Giessen, 35390 Giessen, Germany
  • 2. Ecole Normale Supérieure de Paris, Laboratoire de Météorologie Dynamique, UMR CNRS 8539, 75231 Paris, France
  • 3. UMR CNRS 8591, Laboratoire de Géographie Physique, 92195 Meudon, France
  • 4. Laboratoire des Sciences du Climat et de l'Environement, UMR CEA-CNRS-UVSQ 8212, Domaine du CNRS, 91198 Gif-sur-Yvette, France
  • 5. Institut de Physique du Globe de Paris, Sorbonne Paris Cité, Univ Paris Diderot, UMR 7154 CNRS, 75005 Paris, France
  • 6. Faculty of Science, Masaryk University and Institute of Archaeology, Academy of Sciences of the Czech Republic, 60200 Brno, Czech Republic
  • 7. Institute of Geology, Academy of Sciences of the Czech Republic, 16500 Praha 6, Czech Republic

Description

Dolní Věstonice - Luminescence Dataset

Applicable Licence

CC-BY-NC

Data curators:

Markus Fuchs, Sebastian Kreutzer

Reference original work

Fuchs, M., Kreutzer, S., Rousseau, D. D., Antoine, P., Hatté, C., Lagroix, F., Moine, O., Gauthier, C., Svoboda, J., and Lisá, L.: The loess sequence of Dolní Věstonice, Czech Republic: A new OSL‐based chronology of the last climatic cycle, Boreas, 42, 664–677, https://doi.org/10.1111/j.1502-3885.2012.00299.x, 2013.

How to refer/cite this dataset

Please the information auto-generated by Zendo

Scope

This dataset contains the original luminescence data used to create the chronostratigraphy of the Dolní Věstonice loess profile. By publishing this dataset, we aim to support studies on the general characteristics of luminescence behaviours of natural minerals and support the FAIR guidelines for data sharing. This data is primary unmodified measurement data with all the possible errors and typos!

Please note: The dataset was compiled with the greatest care. However, the dataset comes without any guarantee. Human errors are always possible. If you feel that, after reading the original study and this document, the metadata describing the dataset is insufficient, please contact the data curators so that this document can be updated accordingly. Contrary, the primary cannot be updated/modified!

Dataset structure

The dataset consists of sequence files (SEQ) and measurement data (BIN). To each .bin file, there should be one corresponding sequence file. Measurement data are tagged with sample names in the .bin file, e.g., unless, in case of mistakes, samples can be distinguished in the file. 

  • ...BIN/

    • BIN/A-VALUE/:measurement data with a-value measurements; the alpha irradiation was partly done on an external source

    • BIN/MAIN/ measurement data with data used to estimate the equivalent dose of each sample

    • BIN/PREHEAT_PLATEAU files with combined preheat and dose recovery test results

    • BIN/MISC various additional measurements as indicated by the name

  • ...SEQ/

    • SEQ/A-VALUE/

    • SEQ/MAIN

    • SEQ/PREHEAT_PLATEAU

    • SEQ/MISC

  • ...DE_CSV_EXPORT The extracted equivalent dose values from the measurements with uncertainties in s. 

Please note that samples were partly measured on different machines. All files are selections; in the course of the study, we carried out various additional measurements, in particular, preliminary tests; those data are not included in the dataset to keep the dataset comprehensible. 

Used abbreviations

Abbreviations as used in the measurement and sequence file names. For technical details, we refer to the original study and the reference therein.

ABBREVIATION

TERM

DESCRIPTION

CG

coarse grain

refers to the used grain size fraction, here: 90-200 µm

DRT

dose-recovery test

measurement data with dose recovery test results; in this study, such measurements were carried out in combination with different preheat settings

FG

fine grain

refers to the used grain size fraction, here: 4-11 µm

IRSLT

Infrared stimulated test

test for feldspar contamination

LM

linear modulation

linearly modulated optically stimulated luminescence measurements

MAIN

main measurement

usually, the measurement used to estimate the equivalent dose

MG

medium grain

refers to the used grain size fraction, here: 38-63 µm

mz

Moritz

Name of the used Risø OSL/TL DA-15 reader

mx

Max

Name of the used Risø OSL/TL DA-15 reader

NEU

neu

a German word translating to 'new'

oDRT

oDRT

a typo for just DRT

PreaHeat

preheat test

test against different preheat temperatures

Q

quartz

the measured mineral composition, often in combination with CG , MG , or FG . Example: FGQ : fine grain quartz

Notes

The research was undertaken with the institutional support of the Institute of Geology AS CR, v. v. i. RVO67985831.

Files

Fuchs_et_al_2013_Boreas_LumDataset.zip

Files (78.9 MB)

Name Size Download all
md5:5e638b287ec02e730fc549350fec42d2
78.9 MB Preview Download

Additional details

Related works

Cites
Journal article: 10.1111/j.1502-3885.2012.00299.x (DOI)

Funding

Agence Nationale de la Recherche
ACTES - Abrupt Climatic changes in Terrestrial european Eolian recordS ANR-08-BLAN-0227

References

  • Fuchs, M., Kreutzer, S., Rousseau, D. D., Antoine, P., Hatté, C., Lagroix, F., Moine, O., Gauthier, C., Svoboda, J., and Lisá, L.: The loess sequence of Dolní Věstonice, Czech Republic: A new OSL‐based chronology of the last climatic cycle, Boreas, 42, 664–677, https://doi.org/10.1111/j.1502-3885.2012.00299.x, 2013.