Maximum temperature data from thermal safety assessment of type 21700 lithium-ion batteries with NMC, NCA and LFP cathodes by means of Accelerating Rate Calorimetry (ARC)
Authors/Creators
- 1. Karlsruhe Institute of Technology (KIT), Institute for Applied Materials - Applied Materials Physics (IAM-AWP), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
- 2. Queen's University, Department of Physics, Engineering Physics & Astronomy, 64 Bader Lane, Kingston, ON K7L 3N6, Canada
Description
Data of safety investigation and thermal abuse behavior of commercial type 21700 LIB cells is provided.
It has been acquired with Accelerating Rate Calorimetry (ARC), using a Thermal Hazard Technology type ES ARC.
Moreover, thermal abuse was done by means of the so-called Heat-Wait-Seek (HWS) test, at different states of charge (SOC) from 0 to 100.
Different cathode chemistries are compared (NMC, NCA and LFP), as well as for NCA chemistry, the high energy (HE) and high power (HP) cell design.
For each cell, data includes the maximum temperature measured during thermal abuse at the surface on the center of the cell. Additionally, the mean value and standard deviation for each cell type and state of charge is provided.
This data is supporting this article in the journal Batteries:
https://doi.org/10.3390/batteries9050237
Additional supporting material to this article are the exothermal data for thermal abuse, that are published here:
https://doi.org/10.5281/zenodo.7707929
Files
individual_experimental_measurements_maximum_temperature_thermal_abuse.txt
Files
(3.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:151ab9a55b9518b839681a9c9844cd2f
|
1.8 kB | Preview Download |
|
md5:94ee0df7559e7a9e2a68ca1d15b97850
|
1.3 kB | Preview Download |