Dataset related to article "Multicentric evaluation of a machine learning model to streamline the radiotherapy patient specific quality assurance process"

  • 1. IRCCS Humanitas Research Hospital, via Manzoni 56,20089 Rozzano (Mi) - Italy AND Humanitas University, Department of Biomedical Sciences, Via Rita Levi Montalcini 4, 20072 Pieve Emanuele – Milan, Italy
  • 2. Department of Medical Physics, Hospital Universitari Sant Joan de Reus, IISPV, Tarragona, Spain
  • 3. Department of Radiation Oncology, Hospital Clínic de Barcelona, Barcelona, Spain
  • 4. IRCCS Humanitas Research Hospital, via Manzoni 56, 20072 Rozzano (Mi) - Italy
  • 5. Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy

Description

 This record contains raw data related to article “Multicentric evaluation of a machine learning model to streamline the radiotherapy patient specific quality assurance process"

Purpose: Patient-specific quality assurance (PSQA) is performed to ensure that modulated treatment plans can be delivered as intended, but constitutes a substantial workload that could slow down the radiotherapy process and delay the start of clinical treatments. In this study, we investigated a machine learning (ML) tree-based ensemble model to predict the gamma passing rate (GPR) for volumetric modulated arc therapy (VMAT) plans.

Materials and Methods: 5622 VMAT plans from multiple treatment sites were selected from a database of Institution 1 and the ML model trained using 19 metrics. PSQA analyses were performed automatically using criteria 3%/1 mm (global normalization, absolute dose, 10% threshold) and 95% action limit. Model’s performance was evaluated on an out-of-sample test set of Institution 1 and on two independent sets of measurements collected at Institution 2 and Institution 3. Mean absolute error (MAE), as well as the model’s sensitivity and specificity, were computed.

Results: The model obtained a MAE of 2.33%, 2.54% and 3.91% for the three Institutions, with a specificity of 0.90, 0.90 and 0.68, and a sensitivity of 0.61, 0.25, and 0.55, respectively. Small positive median values of the residuals (i.e., the difference between measurements and predictions) were observed for each Institution (0.95%, 1.66%, and 3.42%). Thus, the model’s predictions were, on average, close to the real values and provided a conservative estimation of the GPR.

Conclusions: ML models can be integrated into clinical practice to streamline the radiotherapy workflow, but they should be center-specific or thoroughly verified within centers before clinical use.

 

Notes

Acknowledgments: NL, DL, and PM are funded by the Italian Ministry of Health (Rome, IT) GRANT_NUMBER: GR-2019-12370739.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

This set of raw data is accessible under request because they include sensitive data.

Please write your request at biblioteca@humanitas.it

You are currently not logged in. Do you have an account? Log in here