Published March 1, 2023 | Version 1.0.0

Shear Shock Waves Mediate Haptic Holography via Focused Ultrasound - Human Hand: Wave Patterns and Perception

  • 1. University of California, Santa Barbara
  • 2. Technische Universität Dresden

Description

Human Hand: Wave Patterns and Perception

This dataset is part of a larger repository (DOI: 10.5281/zenodo.5248082) which houses links to the data used in the publication "Shear Shock Waves Mediate Haptic Holography via Focused Ultrasound" (Reardon et al., 2023). If you use these data please cite our publication (http://www.science.org/doi/10.1126/sciadv.adf2037).

This dataset contains the in vivo response of a single participant's hand to focused ultrasound (UHEV1, Ultrahaptics) scanned in a zigzag path from the wrist to the distal end of digit 2 (and vice-versa). The data is provided as .mat files. The files are separated via longitudinal scanning speed, vl = 1, 2, 4, 7, 11 m/s. At all speeds, the ultrasound focus was modulated transverse to its primary motion direction at a speed, vmod of +-2.5 m/s yielding a zigzag path (2 cm path width). The longitudinal speed is designated in the filename. The direction of scanning - either from the wrist to the distal end of digit 2 (Distal direction) or from the distal end of digit 2 to the wrist (Proximal direction) - is also designated in the filename. Written, informed consent was gathered from the participant in this study, and the protocol was approved by the human subjects committee of our institution. Details about our experimental procedure can be found in our publication.

IMPORTANT - The data is the unprocessed output from a laser doppler vibrometer (PSV-500, Polytec). The data is NOT time-aligned and must be reconstructed using the reference signal and the map of the measurement locations.

 

Data Fields

y (NxMx2) - 3D array containing the skin velocity normal to the laser doppler vibrometer (in m/s) at N measurement locations for M timepoints and 2 repetitions

ref (NxMx2) - 3D array containing a reference voltage signal taken from the ultrasound phased array. The beginning of the reference signal can be used to time-align each of the measurements and repetitions

fs - Laser doppler vibrometer sampling rate (in Hz)

measurementLocations (Nx3) - 3D locations on the hand (x,y,z; in m) for each of N measurement locations

 

 

BehavioralDataset.zip

Contains the responses from three different perception experiments on tactile motion direction discrimination. The experiments are provided in three separate files; the results are provided as a MATLAB table. Written, informed consent was gathered from all participants in this study, and the protocol was approved by the human subjects committee of our institution. Details about our experimental procedure can be found in our publication.

In the first experiment, SSW_PrimaryDataset.mat, participants (N=12) identified the direction of the focused ultrasound as either moving from the wrist to the end of digit 2 (Distal direction) or from the end of digit 2 to the wrist (Proximal direction).

The second experiment, SSW_SecondaryDataset-Zigzag.mat, was nearly identical to the first experiment, except we cyclically repeated the stimuli such that the total integrated time in which the stimulus was applied to the skin was approximately constant between all of the different scan speeds. The participants (N=3) identified the motion direction of the focused ultrasound as either "Distal" or "Proximal" under two conditions - one in which there was no delay between our cyclical repeats (No Delay condition) and a second in which there was a 500 ms time delay between subsequent repetitions (With Delay condition).

The third file, SSW_SecondaryDataset-Circle.mat, presents the pilot results (N=1) of a similar tactile motion experiment, except with circular trajectories (radius 2.8 cm) drawn on the palm of the hand in either a clockwise or counterclockwise direction. The stimuli were also repeated cyclically (with and without delay between repetitions), similar to experiment two.

 

 

Table Fields - SSW_PrimaryDataset.mat

Participant - Participant label

Speed - Longitudinal speed, *v<sub>l</sub>*, of the focused ultrasound stimulus (in m/s)

Response - Participant response as a binary 0 (Distal direction) or 1 (Proximal direction)

Direction - True direction of the stimulus as a binary 0 (Distal direction) or 1 (Proximal direction)

isCorrect - Indicates whether the participant's response matches the true stimulus direction

Repetition - Stimuli were block randomized and "Repetition" refers to how many times the participant has seen that specific stimulus

ResponseLabel - Participant response as either "Distal" or "Proximal"

DirectionLabel - True label of the stimulus as either "Distal" or "Proximal"

Plays - Number of times the participant felt the stimulus before selecting a response

 

Table Fields - SSW_SecondaryDataset-Zigzag.mat

Participant - Participant label

Speed - Longitudinal speed, *v<sub>l</sub>*, of the focused ultrasound stimulus (in m/s)

Response - Participant response as a binary 0 (Distal direction) or 1 (Proximal direction)

Direction - True direction of the stimulus as a binary 0 (Distal direction) or 1 (Proximal direction)

isCorrect - Indicates whether the participant's response matches the true stimulus direction

Repetition - Stimuli were block randomized and "Repetition" refers to how many times the participant has seen that specific stimulus

ResponseLabel - Participant response as either "Distal" or "Proximal"

DirectionLabel - True label of the stimulus as either "Distal" or "Proximal"

Condition - Indicates the experimental condition ("NoDelay" or "WithDelay")

 

Table Fields - SSW_SecondaryDataset-Circle.mat

Participant - Participant label

Speed - Linear speed of the focused ultrasound stimulus along the circular trajectory (in m/s)

Response - Participant response as a binary 0 (Counterclockwise direction) or 1 (Clockwise direction)

Direction - True direction of the stimulus as a binary 0 (Counterclockwise direction) or 1 (Clockwise direction)

isCorrect - Indicates whether the participant's response matches the true stimulus direction

Repetition - Stimuli were block randomized and "Repetition" refers to how many times the participant has seen that specific stimulus

ResponseLabel - Participant response as either "Counterclockwise" or "Clockwise"

DirectionLabel - True label of the stimulus as either "Counterclockwise" or "Clockwise"

Condition - Indicates the experimental condition ("NoDelay" or "WithDelay")

Files

BehavioralDataset.zip

Files (1.9 GB)

Name Size
md5:d6bf176b258e1f94192c618c2909859a
16.8 kB Preview Download
md5:be2a7c1fd0bce4812a6f87bcbe118ea9
262.6 MB Download
md5:533c79562603e4f5961cfa34960f737b
262.8 MB Download
md5:b71fe5ebddc9a04d776d8ffebb497292
202.3 MB Download
md5:e949a888284d955bf5df9c0ed10b1be5
202.3 MB Download
md5:6b55a030c49e4db9e2f7f975223049bb
167.1 MB Download
md5:0deec2391989963ec9324e5692e180b9
167.4 MB Download
md5:e7bb3ce75a283b3a2c6960549f470573
151.3 MB Download
md5:0c2965c6cf2721fc4319d6f0ac5d8ae2
151.5 MB Download
md5:e54f79a68459e3605bc668761d699f9c
147.8 MB Download
md5:6ee11426721afbadccf1a79ca6602df6
147.7 MB Download
md5:5a50e66337ae23f32b4f76a931aeb110
6.6 kB Preview Download

Additional details

Related works

Is continued by
10.5281/zenodo.7686542 (DOI)
10.5281/zenodo.7686550 (DOI)
10.5281/zenodo.7686555 (DOI)
Is part of
10.5281/zenodo.5248082 (DOI)
Is published in
Journal article: 10.1126/sciadv.adf2037 (DOI)

Funding

U.S. National Science Foundation
CAREER: Making Tactile Waves: Somatosensation as Elastic Wave Propagation 1751348