Published October 18, 2022 | Version v1

Tethering zwitterionic polymer coatings to mediated glucose biosensor enzyme electrodes can decrease sensor foreign body response yet retain sensor sensitivity to glucose

  • 1. School of Biological & Chemical Sciences, University of Galway, University Road, Galway, H91 TK33, Ireland
  • 2. Analytical Chemistry–Center for Electrochemical Sciences, Faculty of Chemistry and Biochemistry, Ruhr University Bochum, Universit¨atsstr. 150, 44780, Bochum, Germany
  • 3. Anatomy and Regenerative Medicine Institute (REMEDI), School of Medicine, College of Medicine Nursing and Health Sciences, University of Galway, University Road, , Galway, H91 TK33, Ireland

Description

Foreign body response (FBR) is a major challenge that affects implantable biosensors and medical devices, including glucose biosensors, leading to a deterioration in device response over time. Polymer shields are often used to mitigate this issue. Zwitterionic polymers (ZPs) are a promising class of materials that reduce biofouling of implanted devices. A series of ZPs each containing tetherable epoxide functional groups was synthesised for application as a polymer shield for eventual application as implantable glucose biosensors. The polymer shields were initially tested for the ability to resist fibrinogen adsorption and fibroblast adhesion. All synthesised ZPs showed comparable behaviour to a commercial Lipidure ZP in resisting fibrinogen adsorption. Nafion, a common anionic shield used against electrochemical interferents, showed higher protein adsorption and comparable cell adhesion resistance as uncoated control surfaces. However, a poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) (MPC)-type ZP showed similar behaviour to Lipidure, with approximately 50% reduced fibrinogen adsorption and 80% decrease in fibroblast adhesion compared to uncoated controls. An MPC-coated amperometric glucose biosensor showed comparable current density and a 1.5-fold increase in sensitivity over an uncoated control biosensor, whereas all other polymer shields tested, including Lipidure, Nafion and a poly(ethyleneglycol) polymer, resulted in lower sensitivity and current density. Collectively, these characteristics make MPC-polymer shield coatings an appealing possibility for use in implantable glucose sensors and other implanted devices with the aim of reducing FBR while maintaining sensor performance.

Notes

This project has received funding from the European Union's Horizon 2020 research and innovation program under the Marie Skłodowska-Curie MSCA-ITN "ImplantSens" [813006]. Donation of the CDH by Thomas Reichhart and Roman Kittl (DirectSens GmbH, Klosterneuburg, Austria) and Roland Ludwig, Universität für Bodenkultur Wien (BOKU) Vienna, Austria is gratefully acknowledged. We would like to thank Axel Rosenhahn and Jana Karthäuser from Ruhr University Bochum for the opportunity to perform contact angle measurements.

Files

DOI10.1016j.bios.2022.114815.pdf

Files (8.3 MB)

Name Size Download all
md5:c4b2ad48288b8bec4c83db01613427a5
4.4 MB Preview Download
md5:7a40669d54f6cc74a1c4d21969403005
4.0 MB Download

Additional details

Funding

European Commission
ImplantSens - Mass-transfer independent long-term implantable biosensors 813006