Published February 21, 2023 | Version 1
Dataset Restricted

Aging Test - Pouch Cell - Modules - Part 02 (Module 4)

  • 1. UL Research Institutes
  • 2. Purdue University

Description

Test Sample Specifications

  • Configuration: 5P5S (5 cells in parallel (bank), 5 banks in series) Module
  • Nominal Capacity = 16.5 Ah
  • Graphite / NCA Cells
  • Pouch Cells 

Cycling Protocol

  • Charge: CCCV at C/2 up to 21.0 V and a C/100 cutoff current 
  • Discharge: CC at C/2 down to 13.5 V

Cycling Life

  • Number of Cycles = 1826
  • Capacity Fade = 20.00 %

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

To access the files, send an email to NFP.ElectrochemicalSafety@ul.org with a description of how the data will be used. 

Website: https://ul.org/

You are currently not logged in. Do you have an account? Log in here