Planned intervention: On Wednesday April 3rd 05:30 UTC Zenodo will be unavailable for up to 2-10 minutes to perform a storage cluster upgrade.
Published February 21, 2023 | Version v1
Dataset Restricted

Aging Test - Pouch Cell - Single Cell - Part 13 (Cell 187)

  • 1. UL Research Institutes
  • 2. Purdue University

Description

Test Sample Specifications

  • Nominal Capacity = 3300 mAh
  • Graphite / NCA 
  • Pouch Cell 

Cycling Protocol

  • Charge: CCCV at 1C up to 4.2 V and a C/20 cutoff current 
  • Discharge: CC at 1C down to 2.7 V

Cycling Life

  • Number of Cycles = 2992
  • Aimed Capacity Fade = 18.00 %
  • Actual Capacity Fade = 18.00 %

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

To access the files, send an email to NFP.ElectrochemicalSafety@ul.org with a description of how the data will be used. 

Website: https://ul.org/

You are currently not logged in. Do you have an account? Log in here