Published February 21, 2023
| Version 1
Journal article
Restricted
Aging Test - Pouch Cell - Single Cell - Part 10 (Cell 157)
- 1. UL Research Institutes
- 2. Purdue University
Description
Test Sample Specifications
- Nominal Capacity = 3300 mAh
- Graphite / NCA
- Pouch Cell
Cycling Protocol
- Charge: CCCV at 1C up to 4.2 V and a C/20 cutoff current
- Discharge: CC at 1C down to 2.7 V
Cycling Life
- Number of Cycles = 2264
- Aimed Capacity Fade = 15.00 %
- Actual Capacity Fade = 15.28 %