Aging Test - Pouch Cell - Single Cell - Part 09 (Cell 10)

  • 1. UL Research Institutes
  • 2. Purdue University

Description

Test Sample Specifications

  • Nominal Capacity = 3300 mAh
  • Graphite / NCA 
  • Pouch Cell 

Cycling Protocol

  • Charge: CCCV at 1C up to 4.2 V and a C/20 cutoff current 
  • Discharge: CC at 1C down to 2.7 V

Cycling Life

  • Number of Cycles = 1123
  • Aimed Capacity Fade = 10.00 %
  • Actual Capacity Fade = 10.01 %