Published March 8, 2023 | Version v1

Lysosomal cystine export regulates mTORC1 signaling to guide kidney epithelial cell fate specialization

Description

To identify the factors that drive the metabolic switch induced by CTNS deficiency, we conducted  metabolomics-based profiling of Ctns KO mouse proximal tubule cells ( mPTCs) and wild type controls. 

Sample preparation: Cell pellets (~5×105 cells; n=3 mice per each group) were lysed and extracted with 500mL lysis solution (methanol: water 4:1, v/v) by vortexing for 30 min at 4°C. Precipitated proteins were pelleted by centrifugation (16,000g, for 15 min at 4 °C) and 50uL of the supernatants (50mL) were transferred to a clean Eppendorf vial. The transferred aliquot of the supernatants was kept at 35°C and dried down under a gentle flow of nitrogen. The dried extracts were reconstituted in 20uL water and 80uL injection buffer. 50uL of the reconstituted extract was transferred to a glass vial with narrowed bottom (Total Recovery Vials, Waters) for LC-MS injection. In addition, method blanks, QC standards, and pooled samples were prepared in the same way to serve as quality controls for the measurement. Injection buffer was composed of 90 parts of acetonitrile, 9 parts of methanol and 1 part of 5M ammonium acetate.

Liquid chromatography/mass spectrometry analysis: Metabolites were separated on a nanoAcquity UPLC (Waters) equipped with a BEH Amide capillary column (150 mm x50mm, 1.7mm particle size, Waters), applying a gradient of 5mM ammonium acetate in water (A) and 5mM ammonium acetate in acetonitrile (B) from 5% A to 50% A for 12min. The injection volume was 1mL. The flow rate was adjusted over the gradient from 3 to 2 ml/min. The UPLC was coupled to Synapt G2Si mass spectrometer (Waters) by a nanoESI source. MS1 (molecular ion) and MS2 (fragment) data was acquired using negative polarization and MSE over a mass range of 50 to 1200 m/z at MS1 and MS2 resolution of >20’000.

Untargeted metabolomics data analysis: Metabolomics data sets were evaluated in an untargeted fashion with Progenesis QI software (Nonlinear Dynamics, Waters), which aligns the ion intensity maps based on a reference data set, followed by a peak picking on an aggregated ion intensity map. Detected ions were identified based on accurate mass, detected adduct patterns and isotope patterns by comparing with entries in the Human Metabolome Data Base (HMDB). A mass accuracy tolerance of 5mDa was set for the searches. Fragmentation patterns were considered for the identifications of metabolites. All biological samples were analysed at in triplicate and quality controls were run on pooled samples and reference compound mixtures to determine technical accuracy and stability. List of ranked proteins and metabolites had crossed each other, and the enrichment pathway analysis was performed using the OmicsNet 2.0 software.

Files

data_original_metabolomics.csv

Files (2.5 GB)

Name Size
md5:fcb2222ff0bf025c4ec9c63b269f5095
183.0 kB Preview Download
md5:0a31e99aa6f5e29acf0bed27fec169b6
413.4 MB Preview Download
md5:4c2bbb2d484dd938b3d0d6840cee48ba
408.2 MB Preview Download
md5:cc060bc53da9b69146d2ca4c99756786
404.1 MB Preview Download
md5:3e44b877703151478b7371ab129fd98b
406.7 MB Preview Download
md5:0fa524ea37e4e4342bde8f65a14be3e8
416.2 MB Preview Download
md5:e434533327ccad09a0232a8c3615c388
405.5 MB Preview Download