A Combined Deep Learning System for Automatic Detection of "Bovine" Aortic Arch on Computed Tomography Scans

  • 1. Unit of Radiology, IRCCS Policlinico San Donato, Via Rodolfo Morandi 30, San Donato Milanese, 20097 Milan, Italy
  • 2. DeepTrace Technologies S.R.L., Via Conservatorio 17, 20122 Milan, Italy
  • 3. Clinical Research Unit, Cardiovascular Department, IRCCS Policlinico San Donato, Via Rodolfo Morandi 30, San Donato Milanese, 20097 Milan, Italy

Description

A Combined Deep Learning System for Automatic Detection of “Bovine” Aortic Arch on Computed Tomography Scans

Appl. Sci. 2022, 12(4), 2056; https://doi.org/10.3390/app12042056

Abstract

The “bovine” aortic arch is an anatomic variant consisting in a common origin of the innominate and left carotid artery (CILCA), associated with a greater risk of thoracic aortic diseases (aneurysms and dissections), stroke, and complications after endovascular procedures. CILCA can be detected by visual assessment of computed tomography (CT) chest scans, but it is rarely reported. We developed a deep learning (DL) segmentation-plus-classification system to automatically detect CILCA based on 302 CT studies acquired at 2 centers. One model (3D U-Net) was trained from scratch (supervised by manual segmentation), validated, and tested for the automatic segmentation of the aortic arch and supra-aortic vessels. Three DL architectures (ResNet50, DenseNet-201, and SqueezeNet), pre-trained over millions of common images, were trained, validated, and tested for the automatic classification of CILCA versus non-CILCA, supervised by radiologist’s classification. The 3D U-Net-plus-DenseNet-201 was found to be the best system (Dice index 0.912); its classification performance obtained from internal, independent testing on 126 patients gave a receiver operating characteristic area under the curve of 87.0%, sensitivity 66.7%, specificity 90.5%, positive predictive value 87.5%, negative predictive value 73.1%, positive likelihood ratio 7.0, and negative likelihood ratio 0.4. In conclusion, a combined DL system applied to chest CT scans was developed and proven to be an effective tool to detect individuals with “bovine” aortic arch with a low rate of false-positive findings.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

These data are available upon duly motivated request to the corresponding author of the article

You are currently not logged in. Do you have an account? Log in here