Published January 18, 2023 | Version v1

COD REMOVAL FROM MUNICIPAL WASTEWATER USING ELECTROCOAGULATION BY DIFFERENT AL/FE ELECTRODES

  • 1. Professor, MVPSS, KBT College of Engineering, Nashik, Department of Civil Engineering, Savitribai Phule Pune University, Pune, Maharashtra, India.
  • 2. Faculty, Pimpri Chinchwad Education Trusts Pimpri Chinchwad College of Engineering, Pune, Department of First Year Engineering, Savitribai Phule Pune University, Pune, Maharashtra, India
  • 3. Faculty, Vidya Pratishthans Kamalnayan Bajaj Institute of Engineering and Technology, Baramati, Pune, Department of Civil Engineering, Savitribai Phule Pune University, Pune, Maharashtra, India.

Description

In the present study different combinations of Al and Fe electrodes are used for improving the treatment efficiency in the electrocoagulation (EC) process to purify the domestic wastewater. Various factors are to be studied for the assessment of the COD removal efficiency in the form of pH (3–9), time (10–60 min), and density of current (9.0–40 A/m2). Depending on the influencing factor Al–Al and Fe–Fe able to minimize COD percentage up to 85.0 % and 90% respectively. Similarly 86.0 % and 87.50 % of COD were removed, when aluminium and iron were combined as Al–Fe and Fe–Al respectively. Further, the operating parameters were investigated on the removal of COD. The present study reported that, the combination of electrodes affects greatly on the efficiency of percentage removal of COD using the EC technique.

 

Files

22.pdf

Files (349.6 kB)

Name Size Download all
md5:cb88ec649363ea70ae540e65bbb66c2c
349.6 kB Preview Download