Published November 7, 2022 | Version v1

Results from the FLEX Model for the paper "Impact of variable electricity price on heat pump operated buildings"

  • 1. Technische Universität Wien, Energy Economics Group, Gusshausstrasse 25-29/370-3, 1040 Wien, Austria
  • 2. Fraunhofer Institute for Systems and Innovation Research, Breslauer Str. 48, 76139, Karlsruhe, Germany

Description

The sqlite database contains the results of the Flex model for the Austrian single family house building stock ( insert GITHUB LINK). The building stock is represented by 36 different representative building archetypes (“OperationScenario_Component_Building”). Each building is simulated in twice. In the "reference" mode the energy demand is simply met and indoor comfort is kept constant. In the "optimization" mode the indoor temperature can be varied and thermal storages are charged and discharged minimizing the households energy cost based on a variable electricity price. The sqlite database “Variable_Price_Paper” contains the results for the building stock without any storage implemented. In “Variable_Price_Paper_TS” all buildings have a 750l hot water buffer storage and a 400l DHW storage implemented. The sqlite files SFH_23/25/27 contain the results for a single building where the maximum inside room temperature was changed to 23, 25 and 27 °C respectively.

Following columns were used for generating the results for the Paper:

In the hourly results relevant parameters used in the publication were:

  • ID_Scenario: each building simulated under a different electricity price has a unique scenario number. “OperationScenario” gives an overview of the scenarios.
  • Grid: describes the electricity demand from the grid by the household.

In the yearly results relevant parameters used in the publication were:

  • ID_Scenario
  • TotalCost: represent the yearly operation cost
  • Grid: electricity demand summed up for the whole year

5 different electricity prices are used for scenario generation. The first price is constant, “electricity_2” is the real time price from 2021 plus a hypothetical grid fee of 20cents/kWh. “electricity_3, electricity_4, electricity_5” are prices generated for 2030 for Austria with the Balmorel model. Their profiles can be found under “OperationScenario_EnergyPrice”.

 

Files

Files (3.1 GB)

Name Size
md5:804e782daf7544ee3ad8ce639ba53ad3
1.4 GB Download
md5:55467d1e64728243dd3928ab9fbc28a3
62.2 MB Download
md5:9f8374d9eb840c00467c9f64c77a1034
62.1 MB Download
md5:d2b6302f61829e7711ecb99619279515
62.1 MB Download
md5:a1ba7632fc9adbad13ddb0c303edde77
1.5 GB Download

Additional details

Funding

European Commission
NEWTRENDS - NEW TRENDS IN ENERGY DEMAND MODELING 893311