Published October 28, 2022 | Version v1
Dataset Restricted

Dataset related to article "Automatic Planning of the Lower-Extremities for Total Marrow Irradiation Using Volumetric Modulated Arc Therapy"

  • 1. IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy AND Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20072 Pieve Emanuele, Milan, Italy
  • 2. Department of Medical Physics, Hospital Universitari Sant Joan de Reus, IISPV, Tarragona, Spain
  • 3. University of Milan-Bicocca, Department of Physics "G. Occhialini", piazza della Scienza 2, 20126 Milano, Italy
  • 4. IRCCS Humanitas Research Hospital, Radiotherapy and Radiosurgery Department, via Manzoni 56, 20089 Rozzano, Milan, Italy
  • 5. Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy AND Centre for Health Data Science, Human Techopole, Milan, Italy
  • 6. IRCCS Humanitas Research Hospital, Bone Marrow Transplantation Unit
  • 7. Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milan, Italy
  • 8. Bone Marrow Transplantation Unit

Description

This record contains raw data related to article "Automatic Planning of the Lower-Extremities for Total Marrow Irradiation Using Volumetric Modulated Arc Therapy"

Abstract

Purpose: Total marrow (and lymphoid) irradiation (TMI-TMLI) is limited by the couch travel range of modern linacs, which forces to split the treatment delivery into two plans with opposite orientations: a head-first supine upper-body plan, and a feet-first supine lower-extremities plan. A specific field junction is thus needed to obtain adequate target coverage in the overlap region of the two plans. In this study, an automatic procedure was developed for field junction creation and lower-extremities plan optimization.

Methods: Ten patients treated with TMI-TMLI at our institution were selected retrospectively. The planning of the lower-extremities was performed automatically. Target volume parameters (CTV_J-V98%>98%) at the junction region and several dose statistics (D98%, Dmean, and D2%) were compared between automatic and manual plans. The Modulation Complexity Score (MCS) was used to assess plan complexity.

Results: The automatic procedure required 60-90 minutes, depending on the case. All automatic plans achieved clinically acceptable dosimetric results (CTV_J-V98%>98%), with significant differences found at the junction region, where Dmean and D2% increased on average by 2.4% (p<0.03) and 3.0% (p<0.02), respectively. Similar plan complexity was observed (median MCS=0.12). Since March 2022 the automatic procedure has been introduced in our clinic, reducing the TMI-TMLI simulation-to-delivery schedule by 2 days.

Conclusions: The developed procedure allowed to streamline the treatment planning of TMI-TMLI, increasing efficiency and standardization, preventing human errors, while maintaining the dosimetric plan quality and complexity of manual plans. Automated strategies can simplify the future adoption and clinical implementation of TMI-TMLI treatments in new centers.

 

Notes

Acknowledgments: The AuToMI project is funded by the Italian Ministry of Health (Rome, IT). GRANT_NUMBER: GR-2019-12370739

Files

Restricted

The record is publicly accessible, but files are restricted. <a href="https://zenodo.org/account/settings/login?next=https://zenodo.org/records/7260089">Log in</a> to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

This set of raw data is accessible under request because they include sensitive data.

Please write your request at biblioteca@humanitas.it

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is supplement to
Journal article: 10.1007/s00066-022-02014-0 (DOI)