Published September 27, 2022
| Version v1
Conference paper
Open
Autocalibration Approach for Improving Robustness of Analog ICs
Authors/Creators
- 1. Slovak University of Technology
Description
This work presents a dedicated method of analog integrated circuit (IC) autocalibration, which was used to calibrate a voltage reference with the output voltage value of 96 mV . The reference accuracy might be significantly influenced by fluctuations in the
manufacturing process. The essence of this technique is to suppress this undesired influence of process variations