Development of a Technique to Measure Voltages on CFRP Surfaces during Lightning Direct Effects Testing
Description
This paper demonstrates the successful development of an
easy-to-implement technique for measuring voltages on
Carbon Fibre Reinforced Plastic (CFRP) surfaces during
Lightning Direct Effects (LDE) testing, with careful
management of two key aspects - control of electromagnetic
interference and electrical contact with the CFRP surface.
The work verified that careful minimisation of the size of
voltage measurement loops effectively rendered inductive
coupling to a negligible level. Readily available off-the-
shelf oscilloscope probes were proven to be a suitable
choice, provided that a simple digital Low Pass Filter (LPF)
was used to remove high-frequency noise from
measurements. An epoxy-based method of attaching
measurement electrodes to exposed carbon fibres on the
CFRP surface was demonstrated to be a suitable choice for
both DC and lightning strike testing, whereas a screw-based
method was found to be suitable only for DC testing. Simple
resin abrasion using emery paper, a milling machine, and a
multimeter to determine the point of fibre exposure was
demonstrated to be effective to make electrical contact with
the surface carbon fibres.