Published August 26, 2022 | Version v1

DISPOSAL OF SPENT IONIZATION RADIATION SOURCES COBALT-60

  • 1. PhD, senior researcher, Institute of Nuclear Physics of Academy Sciences, Tashkent, Uzbekistan
  • 2. PhD, Chief Specialist, JSC «Research Institute of Technical Physics and Automation», Moscow, Russia

Description

Abstract
The article discusses the experience work of specialists of the consortium as part of the  INP AS (Tashkent, Uzbekistan), JSC " JSC «Research Institute of Technical Physics and Automation»" and CJSC "Mounting Firm "Radiy" (Moscow, Russia) at utilization of 96 pieces of sources GIK-7-2 Co-60 of gamma installations of "RKhM-gamma-20" and "Issledovatel", including 2 emergency sources Co-60, their burial in specialization point for radioactive waste.   Also, the experience of specialists in the elimination of emergency situation with recharge a highly active source of GIK 8-4 Co-60 for radiation gamma therapy from emergency holder with crack to a new holder from depleted uranium.  The reason for the appearance of a crack on the body of the Co-60 source holder is discussed.

Files

NJD_91-45-48.pdf

Files (581.4 kB)

Name Size
md5:9ee052d47844ed5b959b9d9406a03d77
581.4 kB Preview Download

Additional details

References

  • 1. Code of Conduct on the Safety and Security of Radioactive Sources. 2004. Vein. IAEA. 24.
  • 2. Gamma-installation "Issledovatel". 1969. Technical description and instructions of operation. Moscow. 30
  • 3. Radiation safety standards and basic sanitary rules for ensuring radiation safety. 2006. SanPiN No. 0193-06. Tashkent. 92.
  • 4. Ashrapov U.T., Ergashev Kh.A., Makhkamov Sh.M. 1997. Leak test method source of ionizing radiation. Patent of the Republic Uzbekistan. # 4943.
  • 5. Radionuclide ionizing radiation sealed sources. Leakage test methods. 1992. International Standard ISO 9978-92. Washington. USA. 11.
  • 6. Karnozov A.A. 2000. Issues of protection of fissile materials in nuclear charges. Solving the plutonium problem. Digest of articles. JSC "High-tech Research Institute of Inorganic Materials named after Academician A.A. Bochvar". 92-97.
  • 7. The Convention on the Physical Protection of Nuclear Material. 1980. Information Circular of the IAEA. https://www.iaea.org/sites/default/files/infcirc274r1.pdf
  • 8. Ashrapov U.T., Doroshenko A.A., Nesterov V.P., Tashmetov M.Yu., Filatov K.V. 2017. Elimination of emergency situations with highly active sources of cobalt-60.Questions nuclear science and technology Moscow. 76. 53-56
  • 9. IAEA. 2016. News of the scientific portal "Atomic Energy 2.0" https://www.atomic-energy.ru/news/2016/05/20/66073