Published August 18, 2022
| Version 1.0
Dataset
Open
VBL-VA001: Lab-scale vibration analysis dataset
Description
This dataset is a collection of vibration data (x, y, z) from four machine conditions: normal, bearing fault, misalignment, and unbalance. There are 4000 files, each folder contains 1000 CSV files.
Specification:
- Machine: Panasonic GP –129JXK
- Sensor: enDAQ LOG-0002-100G-DC-8GB-PC Shock & Vibration Sensor
- Length: 5 seconds per CSV file
- Sampling rate: 20 kHz.
Repository for baseline methods: https://github.com/bagustris/vbl-va001.
Refer to our paper for detail: https://link.springer.com/article/10.1007/s42417-023-00959-9
The preprint is also available at ArXiv: https://arxiv.org/abs/2212.1473.
Notes
Files
VBL-VA001.zip
Files
(3.8 GB)
Name | Size | Download all |
---|---|---|
md5:dab0c94b205c88551b9ac54a2754d432
|
3.8 GB | Preview Download |