Published August 12, 2022 | Version v1
Dataset Open

Dataset of impulse responses from variable acoustics room Arni at Aalto Acoustic Labs

  • 1. Aalto University, Department of Signal Processing and Acoustics
  • 2. Aalto University, Department of Signal Processing and Acoustics, Department of Media

Description

A dataset of impulse responses collected in the variable acoustics laboratory Arni at Acoustics Lab of Aalto University, Espoo, Finland.

IRs of 5342 configurations of sound absorption in Arni are included in the dataset. Each of them were measured using an omnidirectional sound source and 5 sound receivers. For each configuration, 5 IRs were captured. The total number of measurements in the dataset is 132 037.

For more information and the reverberation time values estimated from the IRs, please see the paper "Calibrating the Sabine and Eyring formulas" by Karolina Prawda, Sebastian J. Schlecht, and Vesa Välimäki, in The Journal of the Acoustical Society of America

The work leading to producing the dataset and related research was supported by the Nordic Sound and Music Computing Network---NordicSMC, NordForsk project number 86892.

 

How to read the files in the dataset:

The general style of file naming is:
IR_numClosed_NumberOfReflectivePanels_numComb_CombinationNumber_mic_ReceiverNumber_sweep_SweepNumber
for example, for 1 reflective panel, combination 87, IR obtained from 3rd out of 5 sweeps recorded by microphone number 2, the filename is:
IR_numClosed_1_numComb_87_mic_2_sweep_3.wav

The dataset was divided into several files due to its total size. The files included in each .zip file are indicated in its name.

If some of the sound files are missing, e.g. for a certain combination and microphone there are 4 IR recordings instead of 5, it means that the sweep was discarded in the pre-processing phase due to non-stationary noise.
Read more: Karolina Prawda, Sebastian J. Schlecht, and Vesa Välimäki, "Robust selection of clean swept-sine measurements in non-stationary noise", The Journal of the Acoustical Society of America 151, 2117-2126 (2022), doi: https://doi.org/10.1121/10.0009915

The specific combinations with indication whether the panel was in a reflective (represented by figure 0) or an absorptive (represented by figure 1) state are listed in combinations_setup.csv file.
The first column contains the combination number (0--5341), the first row is the panel number (1--55).

Arni_panels_numbers.pdf contains a diagram showing the panel numbers and locations.

Arni_layout.jpg contains a drawing specifying the positions of source source, sound receivers, and other elements of the interior.

 

Files

Arni_layout.jpg

Files (50.9 GB)

Name Size Download all
md5:bad2b39c92aba4941b9d20ffb7ce8429
843.8 kB Preview Download
md5:ec5ba4f36016552edc2cd075a423ece0
15.9 kB Preview Download
md5:6024ff21d2e709d0e20c23b26a8e1542
1.2 MB Preview Download
md5:d3869e72312d9ad51246720baec3e6be
4.3 GB Preview Download
md5:4392753a2c5ca7f71b061c2dfda3f150
9.6 GB Preview Download
md5:b8f9e3af1256b3f3e05cb0cbcb72660f
9.6 GB Preview Download
md5:9d30773258c4c58c19f248d13b999936
9.7 GB Preview Download
md5:8e51d17bf2ce00efe8cc45ac8d0749f7
8.3 GB Preview Download
md5:4f4629251f1469468344ec669f994ea0
9.5 GB Preview Download