A convenient and precise method was developed for simultaneous determination of nickel and cobalt using differential pulse polarography (DPP). Limit of determination of 0.009 µg/ml and 0.04 µg/ ml were achieved for nickel and cobalt, respectively. Major metal ions such as ferric iron, copper, lead and zinc did not interfered.