Dataset related to the article "Computed tomography predictors of structural valve degeneration in patients undergoing transcatheter aortic valve implantation with balloon-expandable prostheses"

Description

This record contains raw data related to the article "Computed tomography predictors of structural valve degeneration in patients undergoing transcatheter aortic valve implantation with balloon-expandable prostheses"

Objectives: Computed tomography (CT) provides excellent anatomy assessment of the aortic annulus (AoA) and is utilized for pre-procedural planning of transcatheter aortic valve implantation (TAVI). We sought to investigate if geometrical characteristics of the AoA determined by CT may represent predictors of structural valve degeneration (SVD) in patients undergoing TAVI with balloon-expandable valves.

Methods: Retrospective study on 124 consecutive patients (mean age:79±7 years; female: 61%) undergoing balloon-expandable TAVI prospectively enrolled in a registry. AoA maximum diameter (Dmax), minimum diameter (Dmin), and area were assessed using pre-procedural CT.  SVD was identified during follow-up with transthoracic echocardiography documenting structural prosthetic valve abnormalities with or without hemodynamic changes.  

Results: The mean follow up was 5.9±1.7 years. SVD was found in 48 out of 124 patients (38%). AoA Dmax, Dmin and area were significantly smaller in patients with SVD compared to patients without SVD (25.6±2.2 mm  vs. 27.1±2.8 mm , p=0.012; 20.5±2.1 mm vs. 21.8±2.1 mm ,p=0.001 and 419±77 mm2  vs. 467±88 mm2,p=0.002, respectively). At univariable analysis, female sex, BSA, 23-mm prosthetic valve size, Dmax <27.1 mm and a Dmin < 19.9 mm were associated with SVD whereas at multivariable analysis, only Dmin <19.9 mm (OR=2.873, 95% CI: 1.191-6.929,p=0.019) and female sex (OR=2.659, 95% CI: 1.095-6.458, p=0.031) were independent predictors of SVD.

Conclusions: Female sex and AoA Dmin < 19.9 mm are associated with SVD in patients undergoing TAVI with balloon expandable valves. When implanting large prostheses in order to avoid paraprosthetic regurgitation, caution should be observed due to the risk of excessive stretching of the AoA Dmin, which may play a role in SVD.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

Please write your request to direzione.scientifica@ccfm.it

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is supplement to
Journal article: 10.1007/s00330-022-08747-x. (DOI)