Dataset related to the article "Cryoballoon atrial fibrillation ablation: Single-center safety and efficacy data using a novel cryoballoon technology compared to a historical balloon platform".

Description

This record contains raw data related to the article "Cryoballoon atrial fibrillation ablation: Single-center safety and efficacy data using a novel cryoballoon technology compared to a historical balloon platform".

 

Abstract

Introduction: Catheter ablation is superior to drugs regarding atrial fibrillation (AF) recurrence, symptoms improvement, and mortality reduction in heart failure. POLARx™ is a novel cryoballoon, with technical improvements seeking to improve outcomes. So far, its clinical evidence is restricted to a case report.

Methods: To compare the POLARx™ cryoballoon procedural safety and efficacy to the already established Arctic Front Advance PRO™ (AFAP) in a single-center cohort study, consecutive patients undergoing AF cryoablation with the POLARx™ were enrolled. Data were prospectively gathered. POLARx™ patients were compared with a historical cohort of patients submitted to AF cryoablation with the AFAP.

Results: Seventy patients were analyzed, 20 in POLARx™, and 50 in the AFAP group. They all underwent first-time pulmonary vein isolation, 77% were male, 94% had paroxysmal AF, median age was 62.5 years, median CHA2 DS2 -VASc 1, left-atrium size 34 ml/m², and 65% were receiving anticoagulation. The primary end-point, all pulmonary veins isolation, was 100% in both groups. The complication rate was similar (0% POLARx™ vs. 5.7% AFAP, p = .39). The median total procedural time was longer in the POLARx™ group (90 min vs. 60 min, p < .001), but the overall time-to-isolation (TTI; 44.8 s vs. 39 s, p = .253) and ablation time (15 min vs. 13.7 min, p = .122) was similar between POLARx™ and AFAP groups, respectively. Despite equal TTI, the POLARx™ had a lower minimal temperature reached (-57°C vs -47°C, p < .001).

Conclusion: The novel POLARx™ cryoballoon had similar efficacy and safety compared with the AFAP. It was also associated with longer procedural times, similar TTI, and lower minimum temperature reached.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

Please write your request to direzione.scientifica@ccfm.it

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is supplement to
Journal article: 10.1111/jce.14930 (DOI)