PERFORMANCE ANALYSIS OF A HYBRID PHOTOVOLTAIC THERMAL (PV/T) SYSTEMh

Authors/Creators

  • 1. University of Engineering and technology Lahore

Description

The gradual increase in the temperature of the photovoltaic panel decreases its efficiency. To eliminate this problem, a thermal collector is attached to the photovoltaic panel to remove heat. It has been found that photovoltaic cell cooling increases the output of electricity and allows the extra heat to be absorbed by the working fluid.
The study includes an experimental investigation of Photovoltaic panel using a rectangular microchannel cooling technique. Water is used as a cooling fluid. An outdoor cooling system was designed to carry out experimentation. A 30 W monocrystalline crystalline photovoltaic panel was selected and rectangular microchannels made of aluminum were attached for heat extraction. The thermal collector is composed of an 8 mm thick microchannel plate of aluminum. The microchannel plate includes 29 channels of 3×3 mm cross-section. The other parts of the test rig include an infrared thermometer, Solar irradiation meter, and multimeter.
K-type thermocouples were installed at inlet and outlet to measure temperature variation in water temperature. Results were drawn against different temperatures and flow rates. An optimum value of the flow rate was found to be 3 L/min. The temperature of the photovoltaic panel decreases with