4D flow evaluation of blood non-Newtonian behavior in left ventricle flow analysis

  • 1. Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • 2. 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy. Electronic address: francesco.sturla@grupposandonato.it.
  • 3. Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
  • 4. Multimodality Cardiac Imaging Section, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
  • 5. Siemens Healthcare GmbH, Erlangen, Germany.
  • 6. Amyloidosis Research and Treatment Center, Fondazione IRCCS Policlinico San Matteo and University of Pavia, Pavia, Italy.

Description

Dataset from Riva A, Sturla F, Caimi A, Pica S, Giese D, Milani P, Palladini G, Lombardi M, Redaelli A, Votta E. 4D flow evaluation of blood non-Newtonian behavior in left ventricle flow analysis. J Biomech. 2021 Apr 15;119:110308. doi: 10.1016/j.jbiomech.2021.110308. Epub 2021 Feb 8. PMID: 33631666.

Abstract

Blood is generally modeled as a Newtonian fluid, assuming a standard and constant viscosity; however, this assumption may not hold for the highly pulsatile and recirculating intracavitary flow in the left ventricle (LV), hampering the quantification of fluid dynamic indices of potential clinical relevance. Herein, we investigated the effect of three viscosity models on the patient-specific quantification of LV blood energetics, namely on viscous energy loss (EL), from 4D Flow magnetic resonance imaging: I) Newtonian with standard viscosity (3.7 cP), II) Newtonian with subject-specific hematocrit-dependent viscosity, III) non-Newtonian accounting for the effect of hematocrit and shear rate. Analyses were performed on 5 controls and 5 patients with cardiac light-chain amyloidosis. In Model II, viscosity ranged between 3.0 (-19%) and 4.3 cP (+16%), mildly deviating from the standard value. In the non-Newtonian model, this effect was emphasized: viscosity ranged from 3.2 to 6.0 cP, deviating maximally from the standard value in low shear rate (i.e., <100 s-1) regions. This effect reflected on EL quantifications: in particular, as compared to Model I, Model III yielded markedly higher EL values (up to +40%) or markedly lower (down to -21%) for subjects with hematocrit higher than 39.5% and lower than 30%, respectively. Accounting for non-Newtonian blood behavior on a patient-specific basis may enhance the accuracy of intracardiac energetics assessment by 4D Flow, which may be explored as non-invasive index to discriminate between healthy and pathologic LV.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

These data are available upon duly motivated request to the corresponding author of the article

You are currently not logged in. Do you have an account? Log in here