Published September 30, 2004 | Version v1

Analytical application of 3-hydroxy-3-p-tolyl-1-m-tolyltriazene in the spectrophotometric determination of molybdenum(VI)

Description

Department of Chemistry, M. L. Sukhadia University, Udaipur-313 001, India
E-mail : akumargoswami@rediffmail.com
Manuscript received 14 October 2003. accepted 4 March 2004

A new reagent 3-hydroxy-3-p-tolyl-1-m-tolyltriazene has been used for the spectrophotometric determination of MoVI at 410
nm, in the pH range 2.3-3.3. Beer's law is obeyed in the range (1 to 6) x 10-5 M. The molar absorptivity and Sandell's sensitivity values are 8004 dm3 mol-1 cm-1 and 11.98 ng cm-2, respectively. The method is useful even in presence of several
cations and anions.