Published April 30, 2008 | Version v1

Sensitive determination of chromium by the catalytic hydrogen wave in the presence of thiocompounds at DME

Description

oepartment of Chemistry, Sri Venkateswara University, Tirupati-517 502, Andhra Pradesh, India

E-mail : nvsnaidu4@gmail.com

P.G. Department of Chemistry, P. B. Siddartha College of Arts & Sciences, Vijayawada-522 010,

Andhra Pradesh, India

Manuscript received 5 September 2007, revised 17 December 2007, accepted 17 December 2007

A sensitive polarographic method for the determination of chromium is proposed, based on the catalytic hydrogen wave of CrVI-xanthate complexes in the presence of NH4Cl at mercury electrode. The CrVI-xanthate complexes produce a catalytic hydrogen wave at -1.52 V vs SCE with potassium propyl xanthate (Kpxan) and at -1.47 V vs SCE with potassium cyclohexyl xanthat.e (Kchxan) in NH4Cl-NH4OH medium (pH 9.6 for Kpxan and 9.2 for Kchxan). The peak height is proportional to metal ion concentration. The proposed method is free of interference from other metal ions except MoVI and is evaluated to micro level CrVI down to 0.1 ppm by the determination of chromium content in drinking water samples, industrial effluents, tannery waste water and agricultural materials.

 