Published December 22, 2021
| Version v1
Dataset
Open
Lock-in and Standard DPC raw images associated to publication 10.1364/PRJ.445896
Description
Raw images obtained with helicam C3 in a DPC microscope setup. The raw images were used for the figures in the publication Chiara Bonati, Damien Loterie, Timothé Laforest, Christophe Moser. Lock-in incoherent differential phase contrast imaging. Photonics Research, 2022, 10(1):237.
Contents of the data set:
- Contrast comparison: images used for Figure 4. Several USAF targets of different height, introducing varying phase differences. Samples were imaged under both standard and lock-in DPC.
- Lock-in DPC: lock-in DPC image sets. Each image was collected over four cycles of 140 us each.
- 5_mrad: 5 mrad sample
- Background: no sample image
- I: Frame I
- Q: Frame Q
- Sample: sample image
- I: Frame I
- Q: Frame Q
- Background: no sample image
- 13dot8_mrad: 13.8 mrad sample
- 15dot1_mrad: 15.1 mrad sample
- 18dot9_mrad: 18.9 mrad sample
- 35dot2_mrad: 35.2 mrad sample
- 50dot5_mrad: 50.5 mrad sample
- 5_mrad: 5 mrad sample
- Standard DPC: Same set of images, under standard DPC conditions. Each illumination (left and right) was recorded for 1 us.
- 5_mrad: 5 mrad sample
- Background: no sample image
- L: Image under left illumination
- R: Image under right illumination
- Sample: sample image
- L: Image under left illumination
- R: Image under right illumination
- Background: no sample image
- 13dot8_mrad: 13.8 mrad sample
- 15dot1_mrad: 15.1 mrad sample
- 18dot9_mrad: 18.9 mrad sample
- 35dot2_mrad: 35.2 mrad sample
- 50dot5_mrad: 50.5 mrad sample
- 5_mrad: 5 mrad sample
- Lock-in DPC: lock-in DPC image sets. Each image was collected over four cycles of 140 us each.
- Reconstruction: Image sets used for figures 5 and 6
- USAF_50dot5mrad: Image sets of a 50.5 mrad glass USAF target.
- Illumination: Folder containing the back-focal plane characterisation of the imaging system, used to compute the transfer functions for phase reconstruction.
- BFP: the back-focal plane aperture of the 0.4 NA objective
- P_1: reduced pupil used in the experiments
- s_L: left source
- s_R: right source
- Lock-in DPC: lock-in DPC image set. The equivalent exposure time was 464 us.
- Standard DPC: standard DPC image set. Each illumination was exposed for 8 us.
- Illumination: Folder containing the back-focal plane characterisation of the imaging system, used to compute the transfer functions for phase reconstruction.
- Onion: Image sets of onion epidermal cells.
- Lock-in DPC: lock-in DPC images for varying equivalent exposure times.
- 104 us
- 120 us
- 136 us
- 152 us
- 168 us
- 184 us
- 200 us
- 216 us
- 232 us
- 248 us
- Standard DPC: Standard DPC image set at 7 us exposure time
- Lock-in DPC: lock-in DPC images for varying equivalent exposure times.
- USAF_50dot5mrad: Image sets of a 50.5 mrad glass USAF target.
Files
Files
(465.8 MB)
| Name | Size | |
|---|---|---|
|
md5:72bd1c72ca0e8ec886702130829acf92
|
465.8 MB | Download |
Additional details
Related works
- Cites
- Journal article: 10.1364/PRJ.445896 (DOI)