Published December 16, 2021 | Version 01

Test and numerical data of a vapour-injection scroll compressor in a heat pump with R1234ze(E)

  • 1. National Center for Scientific Research "Demokritos"
  • 2. , National Technical University of Athens

Description

The dataset contains the experimental results of a water-to-water heat pump tested at the lab for different water temperatures. The refrigerant used is the HFO R1234ze(E). The scroll compressor is equipped with an eco port. The numerical results of a validated semi-empirical model are also included for a standard suction pressure drop model and an improved one.

Files

Files (131.0 kB)

Name Size Download all
md5:aac140008c4de926012d37d8c0618aeb
131.0 kB Download

Additional details

Funding

European Commission
RES4BUILD - Renewables for clean energy buildings in a future power system 814865