Published October 1, 2014
| Version v1
Journal article
Open
Voltammetric simultaneous determination of nickel and cobalt in industrial waste waters
Description
Electroanalytical Research Laboratory, Department of Chemistry, J. N. V University, Jodhpur-342 005,
Rajasthan, India
E-mail : sharma_pk00@yahoo.com
Manuscript received online 03 October 2013, revised 30 May 2014, accepted 30 May 2014
A convenient and precise method was developed for simultaneous determination of nickel and cobalt using differential pulse polarography (DPP). Limits of determination of 0.09 µg/ml and 0.15 µg/ml were achieved for nickel(II) and cobalt(II), respectively. No interference by metal ions such as ferric, copper, lead and zinc was observed.