Published September 1, 2020 | Version v1

A comparative study on Cr(VI) removal by graphene oxide (GO) and functionalized reduced graphene oxide (fRGO)

Description

Department of Civil Engineering, Indian Institute of Engineering Science and Technology, Shibpur,

Howrah-711 103, West Bengal, India

E-mail: sgcoolspandan@gmail.com

Manuscript received online 09 January 2020, accepted 26 June 2020

Effluent mainly from metal processing industry contains toxic hexavalent chromium is a major concern. In this study Cr6+ re­moval was done by graphene oxide (GO) and iron functionalized reduced graphene oxide (fRGO) and a comparative study was carried out. At equilibrium pH 2, fRGO gives more removal than GO. For both the materials, Langmuir adsorption iso­therm fit better than Freundlich isotherm. The adsorption capacities of GO and fRGO are found to be (9.90 mg g–1) and (17.54 mg g–1) respectively. The Langmuir adsorption isotherm constants for GO and fRGO (KL) are found to be (32.90) and (24.08) respectively. Both the materials follow pseudo-second order removal kinetics and fRGO (0.07 g mg–1 min–1) shows faster re­moval rate than GO

(0.03 g mg–1 min–1). It was found that (fRGO) can remove 1.77 times more Cr6+ than graphene oxide (GO). The material can remove 97.22% Cr6+ at optimum pH of 2 and at fRGO dose of 100 mg/100 mL. The method can be used for treating acidic chrome bath effluent effectively.

Files

September 11.pdf

Files (459.6 kB)

Name Size