Published May 20, 2016 | Version v1

Glycerin Oil Injection to Prevent the Deviation of Deep Pressure Gauges in High-Pressure Environments

Authors/Creators

  • 1. Ahwaz Power Generation Management Company, Ramin Power Plant

Description

The most important part of the world's industrial engineering, including power plants, oil companies, petrochemical industries, steel industries, etc., is the control of the instrumentation control unit. The word control and instrumentation find meaning. One of the most important quantities measured in industrial units is the pressure quantity, which requires equipment that, according to environmental conditions and relevant standards, can declare and operate the system pressure correctly and without error. High-vibration environments always deflected the pressure gauges (contagious and simple pressure gauges) and showed a false value. . In such cases, glycerin oil injection in precision instrument pressure gauges was performed in vibrating environments to ensure system reliability. After completing this research, valuable results were obtained. It remained and the problems were solved.

Notes

NAECE01_049

Files

Ghodsi-5.pdf

Files (817.5 kB)

Name Size
md5:7f18a965aa4dea43c7065b87b600bbd6