Published April 30, 2020 | Version v1
Journal article Open

Defining Optimum Location of Shear Wall in an Irregular Building by Considering Torsion

  • 1. Ph. D student, Dr. A.P.J. Abdul Kalam Technical University, Lucknow.
  • 2. Professor, Institute of Engineering and Technology, Lucknow, India.
  • 1. Publisher

Description

In this paper, the optimum or suitable location of shear wall in a high rise irregular shaped building is determined. The criteria of choosing suitable location are well mentioned with suitable examples. We have tested several models in dynamic analysis with the help of ETABS ver. 16. Both Time History and Response Spectrum Methods are performed in the analysis. The paper clearly specifies the causes of torsion in a high rise building as well as it also specifies the ways in which we can control the torsion and storey displacement with the help of shear wall in the high rise buildings.

Files

D6822049420.pdf

Files (848.2 kB)

Name Size Download all
md5:d7fdda4504005c4f2dc84269c3ae91ae
848.2 kB Preview Download

Additional details

Related works

Is cited by
Journal article: 2249-8958 (ISSN)

Subjects

ISSN
2249-8958
Retrieval Number
D6822049420/2020©BEIESP