Published September 7, 2021 | Version v1
Dataset Restricted

Dataset related to article: "Smart Flow for the evaluation of the hemodialysis arteriovenous fistula"

  • 1. Istituti Clinici Scientifici Maugeri IRCCS
  • 2. Istituti Clinici Scientifici Maugeri IRCCS; University of Pavia

Description

We provide the raw data used for the following article:

  • Colucci M, Torreggiani M, Bernardi I, Stangalino S, Catucci D, Esposito V, Sileno G, Esposito C.
    Smart Flow for the evaluation of the hemodialysis arteriovenous fistula. "J Vasc Access". 2020 Sep;21(5):652-657.
    doi: 10.1177/1129729819897171. Epub 2020 Jan 2. PMID: 31894718.


Background: Smart Flow is an innovative tool available on the Carestream Touch Prime Ultrasound machines, which provides automated blood flow measurement and shows the vectors that form the blood flow in the vessel. We compared the use of Smart Flow with traditional Duplex Doppler Ultrasound to evaluate blood flow of arteriovenous fistulas in prevalent hemodialysis patients. Methods: A total of 31 chronic patients on hemodialysis were enrolled. Blood flow was measured on the brachial artery with Smart Flow and duplex Doppler ultrasound. In a subset of 26 patients, a video of the juxta-anastomotic efferent vein was recorded and analyzed to calculate an index of flow turbulence.
Results: We enrolled 21 males and 10 females aged 68.52±11.64 years at the time of evaluation with an average arteriovenous fistulas vintage of 50.23±47.42 months and followed them up for 18.03±5.18 months. Smart Flow and Duplex Doppler Ultrasound blood flow measurements positively correlated (p<0.0001) in the same patient but Smart Flow gave higher blood flow values (995.0 vs 730.3mL/min, p<0.0001), and the Duplex Doppler Ultrasound blood flow standard deviation was similar to Smart Flow (125.4 vs 114.4mL/min, p<0.0001). The time needed to evaluate arteriovenous fistulas with Smart Flow was significantly shorter than Duplex Doppler Ultrasound (67.58±19.89 vs 146.3±26.35 s, p<0.0001). No correlation was found between blood flow turbulence and the subsequent access failure.
Conclusion: Smart Flow is reliable, reproducible, and faster than traditional duplex ultrasound. However, the additional information given by the Smart Flow technique does not seem to add any further benefits in terms of prediction of the access failure

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

Data access requests can be addressed to: direzione.scientifica@icsmaugeri.it

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is source of
Journal article: 10.1177/1129729819897171 (DOI)