Published August 5, 2021
| Version 2
Journal article
Open
DESIGN AND ANALYSIS OF PLC BASED INDUSTRIAL CONTROL SYSTEM
Authors/Creators
- 1. Department of Computer Engineering, The University of Lahore, Lahore Pakistan
Description
We can estimate the solutions to control their worst levels. Some components like the cooling fan, buzzer, and air conditioner will be connected with the relay or simply connected to the PLC board, to get the issues under control. Data will be collected and monitored through HMI.
Files
PJEST-011-GICCL-21(1).pdf
Additional details
References
- [1] Y.An, F.Qin, B. Chen, R. Simon, and H. Wu, "OntoPLC: Semantic Model of PLC Programs for Code Exchange and Software Reuse," IEEE Transactions on Industrial Informatics, vol. 17, pp. 1702-1711, 2020. https://doi.org/10.1109/TII.2020.2997360 [2] M. Kyoung, C. Yeob, and P. Hyun, "A Novel Monitoring System for the Data Integrity of Reactor Protection System Using Blockchain Technology," Journal of Lightwave Technology, vol. 8, pp. 118732-118740, 2020. https://doi.org/10.1109/ACCESS.2020.3005134 [3] T.Klopot, P.Skupin, P.Grelewicz, and J.Czeczot, "Practical PLC-based Implementation of Adaptive Dynamic Matrix Controller for Energy Efficient Control of Heat Sources," IEEE Transactions on industrial Electronics vol. 68, pp. 42689-4278, 2020. https://doi.org/10.1109/TIE.2020.2987272 [4] Y. Wei, Y.Wu, X. Zhang, J. Ren, and D. An, "Fuzzy Self-Tuning PID-Based Intelligent Control of an Anti-Wave Buoy Data Acquisition Control System," IEEE Access, vol. 7, pp. 166157-166164, 2019. https://doi.org/10.1109/ACCESS.2019.2947179 [5] M. M. A. M. Elgenedy, R. Hamila, W. U. Bajwa, A. S.Ibrahim, and N.Al-Dhahir, "Sparsity-Based Joint NBI and Impulse Noise Mitigation in Hybrid PLC-Wireless Transmissions," IEEE Access, vol. 6, pp. 30280-30295, 2018. https://doi.org/10.1109/ACCESS.2018.2842194 [6] G. Guo, " Design and implementation of smart campus automatic settlement PLC control system for Internet of Things.," IEEE Access, vol. 6, pp. 62601-62611, 2018. https://doi.org/10.1109/ACCESS.2018.2877023 [7] Y.Xu, Y.Wu, M.Zhang, and S.Xu, "Sensitivity of Programmable Logic Controllers to Voltage Sags," IEEE Transactions on Power Delivery, vol. 34, pp. 2-10, 2018. https://doi.org/10.1109/TPWRD.2018.2870086 [8] W.Miczulski, M.Krajewski, and S.Sienkowski, "A New Autocalibiration Procedure in Intelligent Temperature Transducer," IEEE Transactions on Instrumentation and Measurement, vol. 68, pp. 895-902, 2018. https://doi.org/10.1109/TIM.2018.2857901 [9] Y.Yamashita, S.Makino, T.Fujisawa, and N.Hanzawa, "PLC-based LP 11 mode rotator with curved trench structure devised from wavefront matching method," IEEE photonics technology letters, vol. 29, pp. 1063-1066, 2017. https://doi.org/10.1109/LPT.2017.2700496. [10] J. D. l. Morenas, A.García-Higuera, and P.García-Ansola, "Shop floor control: A physical agents approach for PLC-controlled systems," IEEE Transactions on Industrial Informatics, vol. 13, pp. 2417-2427, 2017. https://doi.org/10.1109/TII.2017.2720696 [11] A.D.Vieira, E.A.Santos, and A.B.Leal, "A Method for PLC Implementation of Supervisory Control of Discrete Event Systems," IEEE Transactions on Control Systems Technology, vol. 25, pp. 175-191, 2017. https://doi.org/10.1109/TCST.2016.2544702 [12] S.Dominic, Y.Löhr, A.Schwung, and S. X.Ding, " PLC-Based Real-Time Realization of Flatness-Based Feedforward Control for Industrial Compression Systems," IEEE Transactions on Industrial Electronics, vol. 64, pp. 1323-1331, 2016. https://doi.org/10.1109/TIE.2016.2612160 [13] A.Ghosh, S.Qin, J.Lee, and G. N.Wang, "FBMTP: An Automated Fault And Behavioral Anomaly Detection And Isolation Tool For PLC-Controlled Manufacturing Systems," IEEE Transactions on Systems, Man, and Cybernetics: Systems, vol. 47, pp. 3397-3417, 2016. https://doi.org/10.1109/TSMC.2016.2633392 [14] Y.Yamashita, T.Fujisawa, S.Makino, and N.Hanzasa, "Design and fabrication of broadband PLC-based two-mode multi/demultiplexer using a wavefront matching method.," Journal of Lightwave Technology, vol. 35, pp. 2252-2258, 2016. https://doi.org/10.1109/JLT.2016.2641461 [15] N.Hanzawa et al., "PLC-based four-mode multi/demultiplexer with LP 11 mode rotator on one chip," Journal of Light wave Technology, vol. 33, pp. 1161-1165, 2015. https://doi.org/10.1109/JLT.2014.2378281 [16] A.Cataliotti, V.Cosentino, D. D. Cara, S. Guaiana, N.Panzavecchia, and G.Tine, "A new solution for low-voltage distributed generation interface protection system.," IEEE Transactions on Instrumentation and Measurement, vol. 64, pp. 2086-2095, 2015. https://doi.org/10.1109/TIM.2015.2421691 [17] B. F. Adiego, D. Darvas, E. B.Viñuela, J. C. Tournier, and S.Bliudze, "Applying model checking to industrial-sized PLC programs.," IEEE Transactions on Industrial Informatics, vol. 11, pp. 1400-1410, 2015. https://doi.org/10.1109/TII.2015.2489184 [18] J.Han, C. S.Choi, W. K. Park, I. Lee, and S. H.Kim, "Smart home energy management system including renewable energy based on ZigBee and PLC," IEEE Transactions on Consumer Electronics, vol. 60, pp. 198-202, 2014. https://doi.org/10.1109/TCE.2014.6851994 [19] F. J.Sanchez-Pacheco, P. J.Sotorrío-Ruiz, J. R.Heredia-Larrubia, F.Pérez-Hidalgo, and M. S. D. Cardona, "PLC-based PV plants smart monitoring system: field measurements and uncertainty estimation.," IEEE Transactions on instrumentation and measurement, vol. 63, pp. 2215-2222, 2014. https://doi.org/10.1109/TIM.2014.2308972 [20] R.N.Duche and N.P.Swarwade, "Sensor Node Failure Detection Based on Round Trip Delay and Paths in WSNs," IEEE Sensors Journal, vol. 14, pp. 455-465, 2013. https://doi.org/10.1109/JSEN.2013.2284796 [21] R. Eke, A. S. Kavasoglu, and N. Kavasoglu, "Design and implementation of a low-cost multi-channel temperature measurement system for photovoltaic modules," Journal of Instrumentation, vol. 45, pp. 1499-1509, 2012. http://dx.doi.org/10.1016/j.measurement.2012.02.029 [22] H.Carlsson, B.Svensson, F.Danielsson, and B.Lennartson, "Methods for reliable simulation-based PLC code verification," IEEE Transactions on Industrial Informatics, vol. 8, pp. 267-278, 2012. https://doi.org/10.1109/TII.2011.2182653 [23] Z. Aydogmus and O. Aydogmus, "A web-based remote access laboratory using SCADA," IEEE Transactions on education, vol. 52, pp. 126-132, 2009. https://doi.org/10.1109/TE.2008.921445 [24] B. Parashar and G. Taneja, "Reliability and Profit Evaluation of a PLC Hot Standby System Based on a Master-Slave Concept and Two Types of Repair Facilities," IEEE Transactions On Reliability, vol. 56, pp. 534-539, 2007. https://doi.org/10.1109/TR.2007.903151 [25] M.Ioannides, "Design and implementation of PLC-based monitoring control system for induction motor," IEEE transactions on energy conversion, vol. 19, pp. 469-476, 2004. https://doi.org/10.1109/TEC.2003.822303 [26] D. W.Vernooy, J. S.Paslaski, H. A.Blauvelt, R. B. Lee, and K. J.Vahala, "Alignment-insensitive coupling for PLC-based surface mount photonics," IEEE Photonics Technology Letters, vol. 16, pp. 269-271, 2004. https://doi.org/10.1109/LPT.2003.819392 [27] S. I. Naz, J. A. Hussain, B. A. Hafeez, and S. A. Naz., "Tokenization of sindhi text on information retrieval tool" PJEST, vol. 1, pp. 1-7, 2021. http://doi.org/10.5281/zenodo.4774104 [28] K. A. Majeed, Z.Abbas, M. Bakhtyar, Z.Durrani, J. Baber, and I. Ullah, "Face Detectors Evaluation to Select the Fastest among DLIB, HAAR Cascade, and MTCNN," Pakistan Journal of Emerging Science and Technologies, vol. 2, pp. 1-13, 2021. http://doi.org/10.5281/zenodo.5089391. [29] A. A. Noor, M.Bakhtyar, B. A.Chandio, R. Gull, and J. Baber, "Automatic cv ranking using document vector and word embedding" Pakistan Journal of Emerging Science and Technologies, vol. 2, pp. 1-9, 2021. http://doi.org/10.5281/zenodo.5089434