XLS - D3.1: Preliminary assessments and evaluations of the optimum e-gun and injector solution for the CompactLight design
Creators
- Ferrario, Massimo1
- Alesini, David1
- Cardelli, Fabio1
- Castorina, Giovanni1
- Croia, Michele1
- Diomede, Marco1
- Gallo, Alessandro1
- Giribono, Anna1
- Scifo, Jessica1
- Spataro, Bruno1
- Vaccarezza, Cristina1
- Vannozzi, Alessandro1
- Di Mitri, Simone2
-
Rochow, Regina2
-
Latina, Andrea3
- Kelisani, Mohsen Dayyani3
- Doebert, Steffen3
- Angal-Kalinin, Deepa4
-
Clarke, Jim4
- Gazis, Evangelos5
- Aksoy, Avni6
- Luiten, Jom7
- Rajabi, Ali7
- Stragier, Xavier7
- Faus-Golfe, Angeles8
- Han, Yanliang8
- Esperante, Daniel9
- Boronat, Marçà9
- Blanch, César9
- Fuster, Juan9
- Gimeno, Benito9
- 1. INFN - LNF
- 2. Elettra Sincrotrone Trieste
- 3. CERN
- 4. STFC, Daresbury Laboratory
- 5. Institute of Accelerating Systems and Applications
- 6. Ankara University Institute of Accelerator Technologies
- 7. Eindhoven University of Technology
- 8. CNRS - LAL
- 9. CSIC - IFIC
Description
In this deliverable we report an overview of the possible injector options suitable to match the CompactLight X-band high brightness linac able to drive short wavelength FELs user facilities. Different schemes have been investigated including RF gun injectors at different operating frequency (S, C and X band) and a DC gun based design. The electromagnetic and RF designs for all cases are reported and discussed, including a preliminary evaluation of the laser/cathode system requirements. Matchings with the downstream linac are also investigated with beam dynamics simulations. State of the art S-band injectors look appropriate to achieve the required parameters at low repetition rate ( 100 Hz). On the other end a compact C-band (or X-band) RF gun design is expected to have even better performances at low repetition rates and moreover, due to the lower thermal load, could allow higher
repetition rates operation, up to 1 kHz, with acceptable performances degradation. DC guns are also very promising solutions for kHz range operation.
Notes