Published March 8, 2018 | Version v1
Technical note Open

Summary of Studies of SiD ECal Manual Calibration

  • 1. University of Oregon

Description

SiD is one validated detector design for the International Linear Collider with strength in particle flow calorimetery. The silicon-tungsten electromagnetic calorimeter greatly contributes to this. Layers of highly granular (13 mm2 pixels) silicon detectors embedded in thin gaps (∼1 mm) between DENS-24 tungsten alloy plates give the SiD ECal energy resolution on the scale of 20%/ √ E. For use within the full SiD simulation, a robust, nonlinear calibration technique is developed that considers the effect of leakage. This calibration achieves good precision for a wide range of true particle energies all with the calibration error per energy resolution remaining below 3%.

Files

calibLeakage.pdf

Files (1.0 GB)

Name Size Download all
md5:46c8b77be3f69253ae99f88205ef1722
1.4 MB Preview Download
md5:17f04f761b4b74490e641cd01922ef91
1.7 MB Download
md5:8a4af801e3edafee93a3493edc1048ec
418.8 MB Download
md5:5c566e698db785ecfc78e1e4bc9be659
85.2 MB Download
md5:36bb3a9913298125ffdb2ee59f33c489
23.5 MB Download
md5:c03af4f052095d55f73b9d276d504fda
148.0 MB Download
md5:3e55edadcf5ac53c396b7d000ce2af97
31.8 MB Download
md5:414e2fa9470834d034e1161fbe727df7
270.5 MB Download
md5:701d8a3465e36a68d4bb63fe0cdee62b
54.4 MB Download