Published April 16, 2021 | Version v1

Dataset for: arXiv:2101.09003, Thermal noise of a cryo-cooled silicon cantilever locally heated up to its melting point

  • 1. Univ Lyon, ENS de Lyon, Univ Claude Bernard Lyon 1, CNRS, Laboratoire de Physique, F-69342 Lyon, France
  • 2. Ecole Nationale d'Ing ́enieurs de Saint-Etienne (ENISE), F-42100, Saint-E ́tienne, France

Description

  1. The .fig (MATLAB) files correspond to the figures 2c, 3a, 3b, 4a, 4b, 5.
  2. The "data.mat" (MATLAB) file contains the raw data of the experiment for two measurement sessions, named Day1 and Day2. For each set we present:
    1. The list of the laser powers used in the experiment, in the form equilibrium (around 1 mW) - non equilibrium (30 mW) - equilibrium (1mW) - non equilibrium (20 mW)... [e.g. Day1_Powers].
    2. The average temperature of the cryostat at each power [e.g. Day1_Tmin].
    3. An example of the Power Spectrum Density (PSD) at each power, with the corresponding frequency list. [e.g. Day1_PSD,Day1_F]
    4. The totality of the spectra at each power for each resonance mode, in a frequency interval around the resonance, divided into deflection (D_) and torsion (T_) [e.g. Day1_T_PSD, Day1_T_F]. The data are presented in a matrix of the form: (power step x measured spectrum x frequency interval x mode number). Discussing them separately:
      1. The power of each power step is contained in the Day1_Powers list.
      2. The measured spectrum index indicates the measured spectra at given power. This number varies at each power, thus the length of this matrix dimension is set at a maximal value and filled with the available spectra, the other entries being set to "NaN". 
      3. The frequency list (centered around the resonance frequency) has a constant length of around 1000 points for each resonance mode.
      4. The measured modes are up to 9 for deflection and 7 for torsion. Flexural mode 1 is polluted, flexural and torsional mode 5 is not measured due to the probing point being on a node, therefore these entries are set to "Nan". Furthermore, in Day1 we did not measure flexural modes 8 and 9 and torsional modes 6 and 7, which are also set to "NaN" for this set. 
      5. An example is: the 3rd measured spectrum around the 9th flexural resonance at the 2nd power in the list Day1_Powers is: Day1_D_PSD( 2 , 3 , : , 9).

 

 

Files

Files (269.9 MB)

Name Size
md5:dbc711d9c8ab1dab172089df937e9981
143.7 kB Download
md5:aef207fa909cd4111de4504246a915ed
99.0 kB Download
md5:39b1cc39e5ff418d773e5103dcd09988
96.9 kB Download
md5:500ba17a9d29a676c4f7fae65a72e9a3
147.1 kB Download
md5:3111493f6bb3f8c5268f65dd49615295
143.2 kB Download
md5:46cddae449ff8b9fbb3bce1227a6e07c
1.5 MB Download
md5:ef41907ab0e1aab1ac4209a4fa003f23
267.8 MB Download