Published January 6, 2022 | Version 4
Dataset Open

Hyperspectral X-ray CT dataset of a single, iodine-stained lizard head sample

  • 1. University of Manchester
  • 2. University of Veterinary Medicine Vienna

Description

General Data description:

This is a hyperspectral (energy-resolved) X-ray CT projection dataset of a lizard head sample, stained with an iodine contrast agent. It was acquired in a custom-built, laboratory micro-CT scanner with an energy-sensitive HEXITEC detector in the Henry Moseley X-ray Imaging Facility at The University of Manchester.

The following data contains all the files necessary for reconstruction, after a hyperspectral scan was taken of a single, iodine-stained lizard head sample. The iodine contrast agent provided a spectral marker, measured by an energy-sensitive detector, which may be used for spatial mapping and segmentation of stained soft tissue regions.

File descriptions:

Contained are four MATLAB (.mat) data files, as well as a single text (.txt) file.

Lizard_head_scan_parameters.txt provides the full sample and detector geometry of the scan acquisition.

lizard_180Proj_noSupp_1_180.mat contains the full 4D sinogram constructed following flatfield normalisation of the raw projection data. The 4D array contains the total number of energy channels acquired during scanning, vertical and horizontal pixel number, and total projections angles acquired. The data provided is prior to application of any post-processing filters. The first 180 energy channels are included.

lizard_180Proj_Supp_1_180.mat contains the full 4D sinogram constructed following flatfield normalisation of the raw projection data. This dataset is identical to the .mat file above, however here we have also applied a ring-reduction filter, using a wavelet-based Fourier filter which suppresses the presence of ring artefacts in every energy channel. The first 180 energy channels are included.

Energy_axis.mat provides a direct conversion between the energy channels, and the energies (in keV) that they correspond to, following a calibration procedure prior to scanning.

FF.mat contains the 4D flatfield data acquired when no sample was present. This data was used to normalise the projection datasets, as the sinogram was constructed. The first 180 energy channels are included.

Files

Lizard_head_scan_parameters.txt

Files (5.3 GB)

Name Size Download all
md5:d765c496ff159e7d59ec9957d82d782c
1.4 kB Download
md5:bee3f7ca9ad19fe9fe06d1f984ae851f
3.6 MB Download
md5:469433d0bcdbe6ed02073da7e4f4b6d4
1.5 GB Download
md5:0443bbc36295988d41d9a40e2b4ad9aa
1.5 GB Download
md5:ac30aa4e6efbf9a81112efe161719069
328 Bytes Preview Download
md5:26aff3ea905d07842c309d230cd24668
1.6 GB Download
md5:a6f0d4d386da2909b3b4289a8040bb8e
122.9 MB Download
md5:b75b5e49f1bfd464b50b0b05641f9d1c
614.4 MB Download

Additional details

Related works

Is part of
Journal article: 10.1038/s41598-021-00146-4 (DOI)

Funding

UK Research and Innovation
Next Generation Multi-Dimensional X-Ray Imaging EP/M010619/1
UK Research and Innovation
A Reconstruction Toolkit for Multichannel CT EP/P02226X/1
UK Research and Innovation
Tomographic Imaging EP/M022498/1