Published October 31, 2020 | Version 0.0

Estimating TOF from ultrasound signal over bare steel sample of 5 mm thickness

  • 1. CEIT

Description

These data have been obtained using the CEIT ultrasound testbed exciting a PZT piezoelectric sensor with a +/-15 volts pulse located over a 5 mm bare steel sample. The testbed receives the ultrasound response and estimates the TOF measuring the distance between two consecutive echoes. The aim is to develop an embedded system to measure the loss of thickness produced by corrosion.

Files

S355-00-02-YS15-10_echoN_2_20200616130623_nxc_TOF.csv

Files (179.3 kB)

Name Size
md5:8262339d6553ef54f0380803ef8a093c
56.0 kB Preview Download
md5:87525e6b775abeb65ed7686f46d4825c
123.3 kB Preview Download