Visual blood loss estimation using artificial blood versus human blood
Authors/Creators
- 1. Study Program of Midwifery, Akademi Kebidanan Bina Husada, Tangerang, Indonesia
- 2. Balai Pelatihan Kesehatan, West Nusa Tenggara, Indonesia
- 3. Study Program of Midwifery, Poltekkes Tanjungkarang Jurusan Kebidanan, Lampung, Indonesia
- 4. Study Program of Midwifery, Poltekkes Jambi Jurusan Kebidanan, Jambi, Indonesia
- 5. Study Program of Midwifery, Sekolah Tinggi Ilmu Kesehatan Karya Husada Semarang, Indonesia
- 6. Study Program of Midwifery, Sekolah Tinggi Ilmu Kesehatan Bakti Kencana, West Java, Indonesia
- 7. Study Program of Midwifery, Sekolah Tinggi Ilmu Kesehatan Wiyata Husada Samarinda, East Kalimantan, Indonesia
Description
Background. Visual blood loss estimation (BLE) is the most common method used globally.
Aim: To evaluate the accuracy of BLE using artificial blood and human blood as well as consider the correlations, if any, between midwife groups and years of clinical experiences.
Methods. In this observational study, 27 scenarios using artificial blood and 21 scenarios using human blood have been addressed to answer the research question. The primary outcome assessed was the accuracy of visual BLE. The accuracy of which was then correlated to the midwife group and the duration of clinical experience using Cramer’s V test.
Results. A total of 232 participants estimated the blood loss volume, and a trend toward overestimation was found in the visual estimation with artificial blood (AB), but when the simulation used human blood (HB), it tended to be underestimated. There were significant correlations between the midwife groups and estimation accuracy with AB at all volumes, but the correlations were only found at volume 100 mL and 150 mL when the simulation was using HB.
Conclusion. Visual BLE may produce overestimated or underestimated results. Midwives’ skills in estimating blood loss in clinical scenarios using artificial blood cannot be representative of their skills in real labor. The duration of clinical experience does not correlate to the accuracy of BLE. We recommend further studies in order to identify another method that can be implemented in general practice.
Files
967-article.pdf
Additional details
Related works
- Is cited by
- Journal article: 10.13140/RG.2.2.25477.58080 (DOI)
References
- ACOG. (1998). Postpartum hemorrhage. International Journal of Gynecology & Obstetrics, 61(1), 79–86. [Doi:10.1016/s0020-7292(1098)90114-x].
- Beer, H. L., Duvvi, S., Webb, C. J., & Tandon, S. (2005). Blood loss estimation in epistaxis scenarios. The Journal of Laryngology & Otology, 119(1), 16-18. [Doi: https://doi.org/10.1258/0022215053222752].
- Bose, P., Regan, F., & Paterson-Brown, S. (2006). Improving the accuracy of estimated blood loss at obstetric haemorrhage using clinical reconstructions. BJOG, 113(8), 919–924. [DOI: 910.1111/j.1471-0528.2006.01018.x].
- Buckland, S. S., & Homer, C. S. E. (2007). Estimating blood loss after birth: Using simulated clinical examples. Women and Birth, 20(2), 85-88. [Doi: https://doi.org/10.1016/j.wombi.2007.1001.1001].
- Chua, S., Ho, L. M., Vanaja, K., Nordstrom, L., Roy, A. C., & Arulkumaran, S. (1998). Validation of a laboratory method of measuring postpartum blood loss. Gynecologic and Obstetric Investigation, 46(1), 31-33. [Doi: https://doi.org/10.1159/000009992].
- Dildy, G. A., Paine, A. R., George, N. C., & Velasco, C. (2004). Estimating blood loss: Can teaching significantly improve visual estimation? Obstetrics & Gynecology, 104(3), 601-606. [Doi:610.1097/1001.AOG.0000137873.0000107820.0000137834].
- El-Refaey, H., & Rodeck, C. (2003). Post-partum haemorrhage: Definitions, medical and surgical management. A time for change. British Medical Bulletin, 67(1), 205-217. [Doi: https://doi.org/210.1093/bmb/ldg1016].
- Gatch, W. D., & Little, W. D. (1924). Amount of blood lost during some of the more common operations preliminary report. JAMA, 83(14), 1075-1076. [Doi: 1010.1001/jama.1924.02660140033008].
- Haeri, S., & Dildy, G. A. (2012). Maternal mortality from hemorrhage. Seminars in Perinatology, 36(1), 48-55. [Doi: https://doi.org/10.1053/j.semperi.2011.1009.1010].
- Khan, K. S., Wojdyla, D., Say, L., Gülmezoglu, A. M., & Look, P. F. A. V. (2006). WHO analysis of causes of maternal death: A systematic review. The Lancet, 367(9516), 1066-1074. [Doi: https://doi.org/1010.1016/S0140-6736(1006)68397-68399].
- Larsson, C., Saltvedt, S., Wiklund, I., Pahlen, S., & Andolf, E. (2006). Estimation of blood loss after cesarean section and vaginal delivery has low validity with a tendency to exaggeration. Acta Obstetricia et Gynecologica Scandinavica, 85(12), 1448-1452. [Doi: 1410.1080/00016340600985032].
- Lertbunnaphong, T., Lapthanapat, N., Leetheeragul, J., Hakularb, P., & Ownon, A. (2016). Postpartum blood loss: Visual estimation versus objective quantification with a novel birthing drape. Singapore Medical Journal, 57(6), 325-328. [Doi: 310.11622/smedj.2016107].
- Lilley, G., Burkett-st-Laurent, D., Precious, E., Bruynseels, D., Kaye, A., Sanders, J., . . . Collisa, R. E. (2015). Measurement of blood loss during postpartum haemorrhage. International Journal of Obstetric Anesthesia, 24(1), 8-14 [Doi: http://dx.doi.org/10.1016/j.ijoa.2014.1007.1009].
- Meiser, A., Casagranda, O., Skipka, G., & Laubenthal, H. J. (2001). [Quantification of blood loss. How precise is visual estimation and what does its accuracy depend on?]. Anaesthesist, 50(1), 13-20. Retrieved from https://www.researchgate.net/publication/12111630_Quantification_of_blood_loss_How_precise_is_visual_estimation_and_what_does_its_accuracy_depend_on
- Ministry_of_Health. (2014, p. 2). Pusat data dan informasi: Penyebab kematian ibu di Indonesia. Jakarta: Health Ministry of the Republic of Indonesia. Retrieved from https://pusdatin.kemkes.go.id/download.php?file=download/pusdatin/infodatin/infodatin-ibu.pdf
- Ministry_of_Health. (2019). Profil kesehatan Indonesia 2018 [Indonesian health profile 2018]. Jakarta, Indonesia: Ministry of Health of the Republic of Indonesia Retrieved from https://www.kemkes.go.id/download.php?file=download/pusdatin/profil-kesehatan-indonesia/PROFIL_KESEHATAN_2018_1.pdf
- Ministry_of_Health. (2020). Data dan Informasi: Profil Kesehatan Indonesia 2019 [Data and information: Indonesian health profile 2019]. Jakarta: Ministry of Health of the Republic of Indonesia Retrieved from https://www.kemkes.go.id/download.php?file=download/pusdatin/profil-kesehatan-indonesia/Data-dan-Informasi_Profil-Kesehatan-Indonesia-2019.pdf
- Norouzi, N., Bhakta, H. C., & Grover, W. H. (2017). Sorting cells by their density. PLoS ONE, 12(7), e0180520. [Doi: https://doi.org/0180510.0181371/journal.pone.0180520].
- Patel, A., Goudar, S. S., Geller, S. E., Kodkany, B. S., Edlavitch, S. A., Wagh, K., . . . Derman, R. J. (2006). Drape estimation vs. visual assessment for estimating postpartum hemorrhage. International Journal of Gynecology and Obstetrics, 93(3), 220-224. [Doi: 210.1016/j.ijgo.2006.1002.1014].
- Patton, K., Funk, D. L., McErlean, M., & Bartfield, J. M. (2001). Accuracy of estimation of external blood loss by EMS personnel. The Journal of Trauma, 50(5), 914-916. [Doi: 910.1097/00005373-200105000-200100023].
- Prasertcharoensuk, W., Swadpanich, U., & Lumbiganon, P. (2000). Accuracy of the blood loss estimation in the third stage of labor. International Journal of Gynecology & Obstetrics, 71(1), 69-70. [Doi: https://doi.org/10.1016/S0020-7292(1000)00294-00290].
- Razvi, K., Chua, S., Arulkumaran, S., & Ratnam, S. S. (1996). A comparison between visual estimation and laboratory determination of blood loss during the third stage of labour. The Australian and New Zealand Journal of Obstetrics and Gynaecology, 36(2), 152-154. [PMID: 8798302].
- Rosmaria, Indrayani, Anggraini, Y., Lestari, B. C., Kartikawati, S. L., Astuti, L. P., & Ritha, A. (2019). How Indonesian midwives assess blood loss during labor? Pakistan Journal of Medical & Health Sciences, 13(4), 1124-1127. Retrieved from https://www.pjmhsonline.com/2019/oct_dec/pdf/1124.pdf
- Schorn, M. N. (2010). Measurement of blood loss: Review of the literature. The Journal of Midwifery & Women's Health, 55(1), 20-27. [Doi: https://doi.org/10.1016/j.jmwh.2009.1002.1014].
- Statistics_Indonesia, NFPCB, Ministry_of_Health, & Macro_International. (2008). Indonesia demographic and health survey (IDHS) 2007. Jakarta: Statistics Indonesia, National Family Planning Coordinating Board (NFPCB), Ministry of Health, Macro International. Retrieved from http://sdki.bkkbn.go.id/files/buku/2007IDHS.pdf
- Statistics_Indonesia, NPFPB, Ministry_of_Health, & MEASURE_DHS_ICF_International. (2013). Indonesia demographic and health survey (IDHS) 2012. Jakarta, Indonesia: Statistics Indonesia, National Population and Family Planning Board (NPFPB), Ministry of Health, MEASURE DHS ICF International. Retrieved from http://sdki.bkkbn.go.id/files/buku/2012IDHS.pdf
- Tall, G., Wise, D., Grove, P., & Wilkinson, C. (2003). The accuracy of external blood loss estimation by ambulance and hospital personnel. Emergency Medicine, 15(4), 318-321. [Doi: https://doi.org/310.1046/j.1442-2026.2003.00469.x].
- Toledo, P., McCarthy, R. J., Hewlett, B. J., Fitzgerald, P. C., & Wong, C. A. (2007). The accuracy of blood loss estimation after simulated vaginal delivery. Obstetric Anesthesiology, 105(6), 1736-1740. [Doi: 1710.1213/1701.ane.0000286233.0000248111.d0000286238].
- WHO. (2012). WHO recommendations for the prevention and treatment of postpartum haemorrhage. Geneva, Switzerland: World Health Organization. Retrieved from http://apps.who.int/iris/bitstream/handle/10665/75411/9789241?sequence=1).
- Yoong, W., Karavolos, S., Damodaram, M., Madgwick, K., Milestone, N., Al-Habib, A., . . . Okolo, S. (2010). Observer accuracy and reproducibility of visual estimation of blood loss in obstetrics: How accurate and consistent are health-care professionals? Archives of Gynecology and Obstetrics, 281(2), 207-213. [Doi:210.1007/s00404-00009-01099-00408].