Dataset related to article: "Quantitative assessment of the quality of home sleep studies: A computer‐assisted approach"

  • 1. Department of Biomedical Engineering of the Montescano Institute, Istituti Clinici Scientifici Maugeri IRCCS, Pavia, Italy
  • 2. Sleep Unit of the Montescano Institute, Istituti Clinici Scientifici Maugeri IRCCS, Pavia, Italy.
  • 3. Department of Cardiology of the Montescano Institute, Istituti Clinici Scientifici Maugeri IRCCS, Pavia, Italy.
  • 4. Respiratory Function and Sleep Unit of the Montescano Institute, Istituti Clinici Scientifici Maugeri IRCCS, Pavia, Italy.

Description

Abstract

Home monitoring is the most practical means of collecting sleep data in large-scale research investigations. Because the portion of recording time with poor-quality data is higher than in attended polysomnography, a quantitative assessment of the quality of each signal should be recommended. Currently, only qualitative or semi-quantitative assessments are carried out, likely because of the lack of computer-based applications to carry out this task efficiently. This paper presents an innovative computer-assisted procedure designed to perform a quantitative quality assessment of standard respiratory signals recorded by Type 2 and Type 3 portable sleep monitors. The proposed system allows to assess the quality (good versus bad) of consecutive 1-min segments of thoraco-abdominal movements, oronasal, nasal airflow and oxygen saturation through an automatic classifier. The performance of the classifier was evaluated in a sample of 30 unattended polysomnography recordings, comparing the computer output with the consensus of two expert scorers. The difference (computer versus scorers) in the percentage of good-quality segments was on average very small, ranging from -3.1% (abdominal movements) to 0.8% (nasal flow), with an average total classification accuracy from 90.2 (oronasal flow) to 94.9 (nasal flow), a Sensitivity from 0.93 (oronasal flow) to 0.98 (nasal flow), and a Specificity from 0.74 (nasal flow) to 0.86 (abdominal movements). In practical applications, the scorer can run a check-and-edit procedure, further improving the classification accuracy. Considering a sample of 270 unattended polysomnography recordings (recording time: 545 ± 44 min), the average time taken for the check-and-edit procedure of each recording was 6.9 ± 2.1 min for all respiratory signals.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

Please send an enquiry to Scientific Direction, Istituti Clinici Scientifici Maugeri at the following email address:

direzione.scientifica@icsmaugeri.it

Thank you!

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is source of
Journal article: 10.1111/jsr.12899 (DOI)