Published July 10, 2020 | Version v2

Effect of Unloading and Reloading on Bearing Strength of Unconfined Cold-formed Steel Bolted Connections

  • 1. Ph.D. Candidate, ARC Research Hub for Australian Steel Manufacturing, School of Civil, Mining & Environmental Engineering, University of Wollongong, AUSTRALIA
  • 2. Associate Research Fellow, ARC Research Hub for Australian Steel Manufacturing, University of Wollongong, AUSTRALIA.
  • 3. Professor, ARC Research Hub for Australian Steel Manufacturing, School of Civil, Mining & Environmental Engineering, University of Wollongong, AUSTRALIA.

Description

This database presents the experimental investigation of cold-formed steel unconfined double-shear bolted connections where the applied load was stopped at different stages of loading (25% or 65% of the ultimate failure load under monotonic loading) followed by unloading, and finally reloading until failure. A total of 78 bolted connections of cold-formed steel subjected to loading-unloading and reloading condition with sheet thicknesses ranging from 0.55 to 3.0 mm, bolted with 10, 12 or 16 mm bolts were investigated.

Files

Test Data, Unconfined double-shear bolted connection.zip

Files (2.7 MB)

Name Size
md5:559e8fb3d7ebe5121d4caef9fdd3a6f1
2.7 MB Preview Download