Published June 20, 2020 | Version v1

Open-Ended Coaxial Cable Measurements in Diesel-Contaminated soil during Bioremediation

Description

Complex dielectric permittivity was measured over a broad frequency range (200 MHz to 20 GHz) with Keysight 85070D dielectric probe kit connected to a network analyzer (Keysight N5227A), on a series of 6 soil microcosms contaminated with diesel oil, before and after a process of bioremediation. This technology measures separately the real and the imaginary component of complex dielectric permittivity, which are meaningful properties of soil.

Files

Raw_Data.zip

Files (154.4 kB)

Name Size Download all
md5:8ac781cc3eedbb22427b4416bd5c50fd
150.6 kB Preview Download
md5:910ca922410432d034bc24206404485e
3.7 kB Preview Download

Additional details

Related works

Is supplement to
Journal article: 10.3390/s20226677 (DOI)

References

  • Vergnano, A.; Godio, A.; Raffa, C.M.; Chiampo, F.; Tobon Vasquez, J.A.; Vipiana, F. Open-Ended Coaxial Probe Measurements of Complex Dielectric Permittivity in Diesel-Contaminated Soil during Bioremediation. Sensors 2020, 20, 6677.