Published March 13, 2020 | Version v1
Dataset Restricted

Dataset related to article "The Potential Role of Intensity-modulated Proton Therapy in the Regional Nodal Irradiation of Breast Cancer: A Treatment Planning Study."

  • 1. Humanitas Clinical and Research Center – IRCCS -, via Manzoni 56, 20089 Rozzano (Mi) - Italy
  • 2. Humanitas Clinical and Research Center – IRCCS -, via Manzoni 56, 20089 Rozzano (Mi) - Italy AND Humanitas University, Department of Biomedical Sciences, Via Rita Levi Montalcini 4, 20090 Pieve Emanuele – Milan, Italy
  • 3. Department of Biomedical Experimental and Clinical Sciences, University of Florence, Florence, Italy; Radiation Oncology Unit, Az. Osp. Careggi, Florence, Italy.

Description

AIMS:

To investigate the role of intensity-modulated proton therapy (IMPT) for regional nodal irradiation in patients with breast carcinoma in comparison with volumetric-modulated arc therapy (VMAT).

MATERIALS AND METHODS:

A cohort of 20 patients (10 in the breast-conserving surgery group and 10 post-mastectomy patients with tissue expander implants) was investigated. Proton plans were also computed using robust optimisation methods. Plan quality was assessed by means of dose-volume histograms and scored with conventional metrics. Estimates of the risk of secondary cancer induction (excess absolute risk, EAR) were carried out, taking into account fractionation, repopulation and repair.

RESULTS:

Concerning target coverage, the data proved a substantial equivalence of VMAT and IMPT: for example, coverage for the 50 Gy target, expressed in terms of V98%, was 47.8 ± 0.4, 47.6 ± 0.4, 47.3 ± 0.8, consistent with the objective of 47.5 Gy, for post-mastectomy patients for the three groups of patients. Also, the conformality of the dose distributions was similar for the two techniques, about 1.1, without statistically significant differences. Organ at risk planning aims were achieved for all structures for both techniques. The mean dose to the ipsilateral lung was 10.8 ± 1.1, 6.2 ± 0.8, 7.2 ± 1.0; for the contralateral lung was 3.2 ± 0.7, 0.3 ± 0.2, 0.4 ± 0.2; for the contralateral breast was: 3.1 ± 0.7, 0.3 ± 0.3 and 0.3 ± 0.3, whereas it was 3.9 ± 0.9, 0.4 ± 0.3 and 0.5 ± 0.5, respectively, for the heart for VMAT, IMPT and robust IMPT plans over the whole group of patients. Robust optimisation affected the near-to-maximum dose values for contralateral lung and breast, the mean dose for the heart and ipsilateral lung, with a deterioration ranging from 20 to 40% of the nominal value of IMPT plans (e.g. from 8.1 ± 6.4 to 11.4 ± 8.8 for the heart compared with 16.2 ± 5.2 for the VMAT plans). The numerical values of EAR per 10 000 patient-years were about one order of magnitude higher for VMAT than for IMPT for contralateral structures: 11.66 ± 2.01, 0.89 ± 0.80, 0.98 ± 0.77 for the contralateral breast and the three groups of plans, respectively; 14.31 ± 2.75, 1.42 ± 0.80, 1.78 ± 0.87 for the contralateral lung; and 34.86 ± 2.64, 18.85 ± 2.15, 20.98 ± 2.35 for the ipsilateral lung.

CONCLUSION:

IMPT with or without robust optimisation seems to be a potentially promising approach for the radiation treatment of breast cancer when nodal volumes should be irradiated. This was measured in terms of dosimetric advantage and predicted clinical benefit. In fact, the significant reduction in estimated EAR could add further clinical value to the dosimetric sparing of the organs at risk achievable with IMPT.

Files

Restricted

The record is publicly accessible, but files are restricted. Log in to check if you have access.

Request access

If you would like to request access to these files, please fill out the form below.

You need to satisfy these conditions in order for this request to be accepted:

This set of raw data is accessible under request because they include sensitive information.

Please write your request at biblioteca@humanitas.it

You are currently not logged in. Do you have an account? Log in here

Additional details

Related works

Is supplement to
Journal article: 31377082 (PMID)
Journal article: 10.1016/j.clon.2019.07.016 (DOI)