Published April 8, 2019 | Version v2

Experimental and model-based investigation of the effect of the free- surface flow regime on the detection threshold of warm water inflow

Authors/Creators

  • 1. Université François Rabelais de Tours

Description

Experimental and numerical injections of warm water into a free surface flow. Different flow regimes were tested and detection thresholds were determined.

Experiments were done in an outdoor flume, in June 2016. They were monitored by Fiber-Optic Distributed Temperature Sensing with a double-ended configuration and 20s time resolution. Two flume flow rates Q were tested. For each, a few injection flow rates were done, leading to a total of 10 experiments characterized by an injection ratio R. Only calibrated data are uploaded.

Simulations were carried out on HEC-RAS 5.0, a 1D software developed by the US Army Corps of Engineers, and based on the experimental flume geometry. A total of 90 simulations were tested with different flow rates, injection percentage and thermal contrast ∆T  between flowing water and injected water.

Supplementary data can be found to understand the flume geometry, hydraulic characteristics (Reynolds, Peclet and Froude numbers) and exchanges with the atmosphere for both simulations and experiments.

Files

HEC-RAS Simulations.zip

Files (136.4 MB)

Name Size Download all
md5:94d0f3b6b8c492bf8202ff9927415f3c
33.2 MB Download
md5:54205acf7f847d3de292f006587ae468
103.1 MB Preview Download
md5:addf169fa354a6f63824f0ad764be0b4
33.4 kB Download