Published March 5, 2017 | Version v1

DEVELOPMENT AND COMPARISON OF THE VALIDATION METHODS OF HPLC AND UV FOR DETERMINATION OF RANOLAZINE IN PURE FORM AND PHARMACEUTICAL FORMULATION

Description

A new method was developed for the determination of ranolazine using HPLC and UV and their validation by comparing their efficacy in pure and pharmaceutical formulations.The U.V method used different solvent systems and the most solubilizing solvent for ranolazine was found to be methanol and the stock solution were prepared and plotted standard graph and compared with pure drug.The validation were also carried out by determining the precision, accuracy, robustness, specificity, limit of detection and quantitation and reproducibility. The HPLC determination of ranolazine in pure and pharmaceutical formulation was developed and best detected at 273 nm. It utilized Kromasil C 18 column with 5 µm particle size as the stationary phase. The mobile phase consist of methanol and water containing 1% formic acid in the ratio 60:40.The flow rate was 1ml/min and utilized 10 min run time. The calibration curves were also plotted. The method was validated using various parameters.The results from both the UV and HPLC detection showed good agreement with the pure drug and it can be used for the quantitative analysis of ranolazine due to it’s sensitivity and reproducibility.The method was found to be precise, rapid and accurate for determination of ranolazine.

Files

Files (544.8 kB)

Name Size
md5:576419323619cb11218ab93eba6e078b